background image

ClimaCon F

Operating instructions

EN

Summary of Contents for 1155009

Page 1: ...ClimaCon F Operating instructions EN...

Page 2: ......

Page 3: ...F 310 8 3 3 Functional description 8 3 3 1 App connection F 210 F 310 8 3 3 2 Functions in detail 8 3 4 Operating elements and displays 9 3 4 1 ClimaCon F 90 F 100 9 3 4 2 ClimaCon F 210 F 310 9 3 5...

Page 4: ...the heating profile 17 7 2 4 ClimaCon F 210 F 310 Configuration 19 7 2 5 ClimaCon F 210 F 310 Extended settings 20 8 Operation 21 8 1 ClimaCon F 90 F 100 21 8 2 ClimaCon F 210 F 310 21 8 2 1 Auto mod...

Page 5: ...he type plate is located on the inside of the control unit 1 3 Scope of delivery ClimaCon F room thermostat Safety and installation advice 1 4 Contact OVENTROP GmbH Co KG Paul Oventrop Stra e 1 59939...

Page 6: ...3 Safety notes We have developed this product in accordance with current safety requirements Please observe the following notes concerning safe use 2 3 1 Danger to life due to electric current Make su...

Page 7: ...F 100 1 2 3 4 5 Fig 2 Design F 90 F 100 1 Control unit 2 Base plate 3 Terminal strip 4 Opening for the cable feed 5 Release clip 3 Technical description 3 1 Installation scheme example Fig 1 Installat...

Page 8: ...onnected to the setback input slave of a ClimaCon F 90 F 100 room thermostat The voltage at the setback input reduces the temperature at the slave room thermostat by 4 Kelvin compared to the temperatu...

Page 9: ...st protection 6 C 43 F is activated when the room thermostat is switched off Temperature limitation and offset temperature adjustable Master output for controlling the setback temperature of a slave r...

Page 10: ...not exchangeable Colour White Operating voltage 230 V AC 50 60 Hz Protection class II Dimensions WxHxD mm 88x88x25 3 5 1 3 ClimaCon F 100 24 V Parameter Value Temperature adjustment range 12 C to 28...

Page 11: ...For smartphones in portrait format Android 7 x iOS 13 x App languages DE EN FR Dimensions WxHxD mm 88x88x20 3 5 2 3 ClimaCon F 310 24 V Parameter Value Temperature adjustment range 12 C to 28 C frost...

Page 12: ...tect from sunlight Chemical influences Do not store together with aggressive media 6 Installation WARNING Danger to life due to electric current There is a danger to life if live components are touche...

Page 13: ...a standard flush mounted box For mounting and installing the actuators you use observe the respective operating instructions Fig 7 Mounting of the base plate 1 Hold the base plate flat against the wal...

Page 14: ...IN L1 24 V AC change over L1 L1 L1 1 2 3 4 5 L2 CO L1 L2 SELV 6 4 1 4 ClimaCon F 210 230 V item no 1155021 Terminal Assignment 1 IN L 230 V operating voltage 2 IN N 230 V operating voltage 3 OUT L 230...

Page 15: ...tages at the terminals for potential free contacts Only apply extra low voltages SELV to terminals 9 and 10 f Connect the cores to the terminal strip according to the terminal assignment for your prod...

Page 16: ...tivation of the teach in mode Z The Eco mode and Auto mode key flash alternately The display shows BLu The teach in mode is active The teach in mode remains active for approx 1 minute Without teach in...

Page 17: ...ol turns grey ClimaCon F 310 Depending on whether heating or cooling is signalled to the room thermostat at the change over connection the corresponding symbol is displayed here 7 2 2 ClimaCon F 210 F...

Page 18: ...identical temperature curves for each day of the week Mo Fr Sa Su With this weekly profile you configure uniform values for the working days and individual different values for Saturday and Sunday Mo...

Page 19: ...7 2 4 2 Operating mode The currently set operating mode Heating or Cooling is displayed here The corresponding setting can be changed in the Extended settings menu Fig 19 on page 20 7 2 4 3 Correctio...

Page 20: ...ho are sufficiently qualified 7 2 5 1 Unit Here you can choose between the units Celsius and Fahrenheit This setting affects all temperature settings in the app and at the room thermostat 7 2 5 2 Oper...

Page 21: ...oint temperature with the rotary wheel position 1 in Fig 4 on page 9 Observe the notes on the function of the setback output master in par 3 3 1 2 on page 8 8 2 ClimaCon F 210 F 310 8 2 1 Auto mode Au...

Page 22: ...n function is automatically deactivated The message F1 appears in the display The device has measured implausible temperature values or the temperature measurement has failed Contact the technical ser...

Page 23: ......

Page 24: ...115500983 V02 01 2022 Oventrop GmbH Co KG Paul Oventrop Str 1 59939 Olsberg Tel 49 2962 820 Fax 49 2962 82400 mail oventrop com www oventrop com...