CARE AND MAINTENANCE

CAUTION:

Notices

Before Each Use

Cleaning Surfaces

Storage

During periods of extended inactivity or when transporting:

All cleaning and maintenance should be done when fire pit is cool and with the fuel

supply disconnected.

1. 

DO NOT clean any outdoor fire pit part in a self cleaning oven. The extreme heat will damage the finish.

2. 

Do not enlarge valve orifices or burner ports when cleaning the valves or burners.

1. 

This outdoor fire pit should be thoroughly cleaned and inspected on a regular basis.

2.  Abrasive cleaners will damage this product.

3. 

Never use oven cleaner to clean any part of outdoor fireplace.

1. 

Keep the outdoor fire pit area clean and free from any combustible materials, gasoline, and other flammable 

vapours and liquids.

2. 

Do not obstruct the flow of the combustion of LP and the ventilation air.

3. 

Keep the ventilation opening of the LP gas tank area free and clear from debris.

4. 

Visually check the burner flames to make sure your outdoor fire pit is working properly.

5.  See sections below for proper cleaning instructions.
6.  Check all gas connections for leaks.
7.  Check components for any signs of damage or rust.
8.  Check and clean the burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire 

beneath the outdoor fire pit.

9.  If damage to any component is detected, do NOT operate until repairs are executed.

1.  Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water.
2.  For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush.
3.  Rinse clean with water.
4.  Allow to air dry.

Before each use of appliance, inspect the hose and make sure to properly locate the gas. Always inspect 

the hose for evidence of excessive abrasion, cuts or wear prior to use, and make sure to leak test. The hose 

assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive 

abrasion or wear or if the hose is damaged. The replacement hose assembly shall be that specified by the 

manufacturer.

Between uses:

• 

Turn control knob OFF.

• 

Disconnect LP source.

•  Store fire pit upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, 

snow, dust and debris).

•  If desired, cover fire pit to protect exterior surfaces and to help prevent build-up in air passages.

     Note: Wait until fire pit is cool before covering.

•  Turn Control Knob OFF.
• 

Disconnect LP source and move to a secure, well-ventilated location outdoors.

•  Store fire pit upright in an area sheltered from direct contact with inclement weather (such as rain, sleet, hail, 

snow, dust and debris).

•  If desired, cover fire pit to protect exterior surfaces and to help prevent build-up in air passages. Never leave 

LP cylinder exposed to direct sunlight or excessive heat.

     Note: Wait until fire pit is cool before covering.

Figure 236, Page 22

Summary of Contents for G18002-3

Page 1: ...N FOR FUTURE REFERENCE READ CAREFULLY MADE IN CHINA Questions problems missing parts Before returning to your retailer call our customer service department at 1 866 839 2888 8 a m 5 p m EST Monday Fri...

Page 2: ...t and caution demanded will reduce the possibilities of personal injury or property damage The following symbols shown below are used extensively throughout this manual Always heed these precautions a...

Page 3: ...ding matches lighters sparks or open flames of any kind many feet away from the original leak Use only propane gas set up for vapor withdrawal Store or use propane gas in compliance with local ordinan...

Page 4: ...ustment alteration service or maintenance can cause property damage injury or death Read the installation operation a nd m a i nte na nc e i nstructions thoroughly before installing or servicing this...

Page 5: ...re pit is on a hard and level surface 13 There are no signs of spider or insect nests 14 All burner passages are clear 15 All air circulation passages are clear 16 Children and adults should be alerte...

Page 6: ...EXPLODED VIEW Figure 236 Page 6 Glass bead 4kg x 2 box Burner Table top Knob Control panel Ignitor Valve assembly and LP hose LP Reducer NG Reducer NG Hose Table base Top cover...

Page 7: ...ASSEMBLY INSTRUCTIONS FOR LP Step 1 Step 2 Figure 236 Page 7...

Page 8: ...ASSEMBLY INSTRUCTIONS FOR LP Step 3 Step 4 Figure 236 Page 8...

Page 9: ...he orifice B Connect the natural gas gray pipe Orifice size NG 3 66mm LPG 2 12 mm LP transformation part list LP reducer with 2 12 mm orifice NG reducer with 3 66 mm orifice LP hose assembly NG hose a...

Page 10: ...ASSEMBLY INSTRUCTIONS FOR NG Step 2 Step 3 Figure 236 Page 10...

Page 11: ...ASSEMBLY INSTRUCTIONS FOR NG Step 4 Step 5 LP reducer Figure 236 Page 11 2 12...

Page 12: ...ASSEMBLY INSTRUCTIONS FOR NG Step 6 Step 7 NG reducer Figure 236 Page 12 3 66...

Page 13: ...ASSEMBLY INSTRUCTIONS FOR NG Step 8 Step 9 Figure 236 Page 13...

Page 14: ...ASSEMBLY INSTRUCTIONS FOR NG Step 10 Step 11 Natural Gas Inlet Figure 236 Page 14...

Page 15: ...rmation in these instructions are not followed exactly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency...

Page 16: ...l it is loose Caution LP gas tank must be properly disconnected and removed prior to moving this pit 1 A professionally installed shut off valve between the supply piping and the socket is recommended...

Page 17: ...knob counter clockwise until fully opened If you hear a rushing sound or smell gas turn the gas off Tighten any leaking connections If the leak is detected at connection nut and tightening does not st...

Page 18: ...BATTERY INSTALLATION 1x AAA Battery included Figure 236 Page 18...

Page 19: ...STORAGE FOR TABLE COVER Step 1 Step 2 Step 3 Figure 236 Page 19...

Page 20: ...d turn control knob couter clockwise to LOW Hold the knob until just before the flames go out 5 Press the IGNITION button and hold for up to 5 seconds to light burner 6 Release control knob after 45 s...

Page 21: ...and orifices for blockage Remove blockage and clean burner inside and outside Turn cylinder valve OFF and fill the cylinder Blockage in orifice Control knob is not in ON position Gas pressure is low...

Page 22: ...nt is detected do NOT operate until repairs are executed 1 Wipe surfaces clean with mild dishwashing detergent or baking soda mixed with water 2 For stubborn surfaces use a citrus based degreaser and...

Page 23: ...STONE OR CERAMIC TOPS Don t use harsh abrasive cleansers on any of these products For daily maintenance use a wet cloth and a soft liquid cleaner MAINTENANCE Store in a dry area out of the elements o...

Reviews: