DMX-512 connection/connection between fixtures

Occupation of the XLR-connection:

1. Group

2. Signal (-)

3. Signal (+)

DMX OUT

1. Group

2. Signal (-)

3. Signal (+)

DMX IN

If you are using controllers with this occupation, you can connect the DMX-output of the controller di

-

rectly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers 
with other XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture.
Always connect one output with the input of the next fixture until all fixtures are connected.

DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an electrically noisy environ

-

ment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing 
corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug 
with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket 
of the last fixture in the chain.

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω 

resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the 
last fixture.

Power connection

Power Requirements
The Panto Leko 60 luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire 
contains an auto-ranging power supply.

Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.

The occupation of the connection cables as below:

Cable color

Connection

International

Brown 

Live

L

Blue 

Neutral

N

Yellow/green

Earth(Ground)

Operation

The Panto Leko 60 can operate in three different modes. In each mode you can run the fixture as a 
stand alone fixture or in a master/slave confiugration. This next section will detail the differences in the 
operating modes.

Summary of Contents for PANTO LEKO 60

Page 1: ...USER MANUAL PANTO LEKO 60 60W tunable LED profile zoom...

Page 2: ...ning the fixture to a flat surface 4 Mounting the fixture on a truss 4 Securing with a safety cable 4 DMX 512 connection connection between fixtures 5 Power connection 5 Operation 5 Addressing 6 Unive...

Page 3: ...ion and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the p...

Page 4: ...tion When installing the fixture hanging vertically down you can use an open type clamp such as a G clamp When installing in any other orientation you must use a half coupler clamp that completely enc...

Page 5: ...reventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3 which is then plugged into the output...

Page 6: ...n to the channel number you have set based on the quantity of control channels of the unit That means changing the settings of one channel will af fect only the selected fixture In the case of the Pan...

Page 7: ...0F 12F 24F PWM frequency adjustment KHz DMX Protocol 1 Channel Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer 2 Channel Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer C...

Page 8: ...stened with a weak deter gent solution Do not rub glass surfaces hard lift particles off with a soft repeated press Dry with a soft clean lint free cloth or low pressure compressed air Remove stuck pa...

Reviews: