![Ovation Grid-Lok Installation Manual Download Page 21](http://html1.mh-extra.com/html/ovation/grid-lok/grid-lok_installation-manual_1662247021.webp)
CHAPTER 7
Adjustments and settings
Issue 1
Grid-Lok Installation Manual
19
Adjusting
the module
timing
The timing from the table up to the Grid-LokTM Pin up may be
adjusted. This may be required if the table start and the pin Up
timing needs to be delayed. To adjust the individual table/Pin Up
timing air control regulator, use the following procedure:
1. Remove the cover from the 411_CTL control Box
2. Locate the 4 Control Boards
3. Adjust the potentiometer labeled D1, D2, D3 and D4 in the
picture below. D1 = Table A1, D2 = Table A2, D3 = Table B1 and D4 =
Table B2
4. Each increment is 50ms of time. 0 = No Delay.
5. Once the required delay is set, gently replace the 411_CTL cover
ensuring all control boards are correctly inserted and no wires are
pinched between the cover and main control box cover