16
allowable code length. Code length limitations
can be set in 2 ways :
Fixed Code Length
and
Max / Min code length
. If the fixed code
length is selected, up to 2 fixed lengths can be
specified. And if max / min code length is
selected, the max length and the min length
must be specified, and the scanner will only
accept those codes with lengths fall between
max / min length specified.
4.10 Plessey
•
Convert to UK Plessey
: If this parameter is
enabled, the scanner will change each
occurrence of the character ‘A’ into character
‘X’ in the code.
•
Checksum Transmission
: If this parameter is
enabled, the checksum characters (two
characters) will be transmitted together wi th
data.