LP SAFETY:

a.   Do not store a spare LP-gas cylinder under or  

near this appliance. 

b.  Never fill the cylinder beyond 80 percent full. 
c.   If the information in “(a)” and “(b)” is not followed exactly, a 

fire causing death or serious injury may occur.

Do not use this appliance under overhead combustible surfaces.

MINIMUM CLEARANCES:

•  Bottom: Non-Combustible Surface
•  Top: 80 inches
•  Sides: 36 inches
•   For Installation on (or over) non-combustible floors only

Max. Input:  

58,000 BTU/h (17.0kW) 

Max Gas Supply Pressure:  

250 PSI

This appliance shall be used only outdoors in a well-ventilated 
space and shall not be used in a building, garage or any other 
enclosed area. 

If this appliance is not in use, the gas must be turned off at the 
supply cylinder.

Indoor storage of this appliance is permissible only if the cylinder 
is disconnected and removed from the appliance. 
Cylinders must be stored outdoors in a well-ventilated area out of 
the reach of children. 

Disconnected cylinders must have threaded valve plugs tightly 
installed and must not be stored in a building, garage or any 
other enclosed area. 

The gas pressure regulator provided with this appliance must be 
used, and must be the same model as supplied with the unit. 

The cylinder supply system must be arranged for vapor 
withdrawal. 

Cylinders used with this unit must have a collar to protect the 
cylinder valve. 

An approved LP-Cylinder stabilizer, such as the stabilizer ring 
included, must be used when the appliance is in use.

Replacement parts and a list of such parts are available from FMI 
Brands Inc. through the contact information provided on the last 
page of this Manual.

 Please ensure that all adults and children which use or are 
near a unit in use are aware of the hazard of high-surface 
temperatures present on the unit during use and should use 
caution and stay away to avoid burns or clothing ignition. 

Carefully supervise young children in the area of this appliance. 
Clothing or other flammable materials should not be hung from 
the appliance or placed on or near the appliance. Any guard or 
other protective device removed for servicing the appliance 
must be replaced prior to operating the appliance. 

Installation and repair should be done by a qualified service 
person. The appliance should be inspected before use and 
at least annually by a qualified service person. More frequent 
cleaning may be required as necessary. It is imperative that 
control compartment, burners and circulating air passageways 
of the appliance be kept clean. 

 

 WARNING:

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Read 
the installation, operating and maintenance instructions 
thoroughly before installing or servicing this equipment.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life.
Installation and service must be performed by a qualified 
installer, service agency or the gas supplier.

Summary of Contents for FMPPC2A-2

Page 1: ...D 893 000 V0 Owner s Manual FMI BRANDS INC 309 19133 26th Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 Model number FMPPC2A 2 Series number 893...

Page 2: ...liance 2 Extinguish any open flame 3 If odour continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Do not store or use gasoline or other flammable v...

Page 3: ...stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information...

Page 4: ...rovided at floor level of the enclosure and shall have total free area of not less than 1 2 in2 per lb 7 1 cm2 per kg of stored fuel capacity If ventilation openings at floor level area are in the sid...

Page 5: ...ontact FMI Brands Inc should you require a replacement hose Inspect burner prior to each use Burner must be replaced prior to the appliance being put into operation if there is evidence of damage Repl...

Page 6: ...storage and transportation as shown Note Rocks are not to exceed a maximum weight of 2 kgs or 4 4 lbs Never use a lid to extinguish the flame on your Outland Firebowl The lid and carry straps Cover C...

Page 7: ...inspecting the burner to ensure the presence of flames STEP 6 Using a lighter or match ignite lighter and hold flame slightly above the burner then open the valve on the appliance slowly by turning c...

Page 8: ...me for your Outland Firebowl using a full 20 lb 9kg propane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only when...