Outland Firebowl FMPPC2B-4 Owner'S Manual Download Page 5

LEAK TEST:

1.  

DO NOT USE OR PERMIT SOURCES OF IGNITION  
IN THE AREA WHILE DOING THE LEAK TEST. 
THIS INCLUDES SMOKING.

2.  

Leak testing should be done once per year or whenever the 
LP gas cylinder or any other gas system part is taken apart, 
serviced or replaced, whichever is more frequent.

3.   Ensure all gas system coupling joints are tight  

and properly attached.

4.   Prepare a leak testing solution of half liquid detergent  

and half water.

5.   Apply the solution to the LP gas delivery system at points  

as shown in illustration indicated on page 3.

6.  

The leak(s) must be stopped by tightening the loose joints, 
if possible, or by replacing the faulty parts(s) with the part(s) 
recommended by the appliance manufacturer.

THE APPLIANCE IS NOT TO BE USED UNTIL ANY LEAK IS 
CORRECTED.

A gas appliance repairman or LP gas dealer should be called if 
attempts to stop the leak(s) are unsuccessful and, in such case, the 
LP gas supply must be shut off at the cylinder valve or the cylinder 
must be removed from the appliance until the leak(s) is corrected.

Inspect hose prior to each use of the unit. The hose assembly 
must be replaced prior to the appliance being put into operation 
if there is evidence of excessive abrasion or wear, or if the hose 
is damaged. Contact FMI Brands Inc. should you require a 
replacement hose.

Inspect burner prior to each use. Burner must be replaced prior 
to the appliance being put into operation if there is evidence of 
damage. Replacement burners are available from FMI Brands Inc.

Should any part of this appliance (including the burner) become 
soiled or dirty, wipe lightly with a damp cloth. Do not use 
flammable or corrosive cleaning products on or near this unit.

Ensure that gas hose is placed in an area where it is unlikely to 
be tripped over (such as pathways or trails) or subject to other 
accidental damage.

Keep the appliance area clear and free from combustible 
materials, gasoline and other flammable vapors and liquids.

Solid fuels shall not be burned in this appliance. 

Installation must conform with local codes or, in the absence of 
local codes, with either the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1 or 
Propane Storage and Handling Code, B149.2, or the Standard  
for Recreational Vehicles, ANSI A 119.2/NFPA 1192, and CSA Z240 
RV Series, Recreational Vehicle Code, 
as applicable.

NOTE TO INSTALLER: 

Leave this guide with the consumer.

NOTE TO CONSUMER: 

Please retain this guide for future use.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life. Installation and service must 
be performed by a qualified installer, service agency or the 
gas supplier.

En-4

  1-888-514-1663  |  

WWW.OUTLANDLIVING.COM

Summary of Contents for FMPPC2B-4

Page 1: ...FMI BRANDS INC 107 19052 26 Avenue Surrey B C Canada V3Z 3V7 Toll Free 1 888 514 1663 Fax 1 888 797 9931 D 883 000 V1 Owner s Manual Model number FMPPC2B 4 Series number 883...

Page 2: ...For outdoor use only CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odour Using it in an enclosed space can kill you Never use this appliance in an enclosed space such...

Page 3: ...ncluded must be used when the appliance is in use Replacement parts and a list of such parts are available from FMI Brands Inc through the contact information provided on the last page of this Manual...

Page 4: ...ntilated by openings at both the upper and lower levels of the enclosure This shall be accompanied by one of the following a One side of the enclosure shall be completely open or b For an enclosure ha...

Page 5: ...replacement hose Inspect burner prior to each use Burner must be replaced prior to the appliance being put into operation if there is evidence of damage Replacement burners are available from FMI Bran...

Page 6: ...EP 6 Your included Cover is to be used for storage and transportation as shown in the following image Never use the cover to extinguish the flame on your Outland Firebowl SECTION 2 IGNITION STEP 1 Ens...

Page 7: ...ns See section labeled Leak Test WARNING Ensure that no parts of your body clothing or any other combustible material are above the burner before during and after ignition Ensure the cover is stored s...

Page 8: ...time for your Outland Firebowl using a full 20 lb 9kg propane cylinder is between 7 and 11 hours depending on where the flame height is set FMI Brands Inc recommends that you ignite this unit only wh...

Reviews: