Operating Instructions
Checking Connections & Leaks
Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check the connection between the burner pipe and opening. Make sure the burner pipe
fits over the opening.
Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.
Attach the hose to control valve, make sure control knobs are off.
Turn LP gas tank ON at valve.
Spoon leak check solution at the “x” location.
If any bubbles appear, turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts, turn off LP
gas tank and disconnect LP gas source.
If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
WARNING: Failure to inspect this connection or follow these inspections could cause a fire or explosion which can cause
death, serious bodily injury, or damage to property. (Please refer to diagram for proper installation).
Tank/Gas Line Connection
Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.
Make sure control knobs are off.
Turn LP gas tank ON at valve.
Spoon leak check solution at all “x” locations.
If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts, turn off LP
gas tank and disconnect LP gas source.
If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
x
x
x
x
x
X
Gas connection
Gas valve
with orifice
Burner
venturi pipe
Main Valve