SET-UP
STEP 2
CONNECT THE GAS LINE
STEP 2.1
CONNECTION FOR LIQUID PROPANE
Location of Gas Inlet
This applies to both liquid propane and natural gas
installation.
Your fire pit will come Pre-Plumbed for the appropriate
gas feature that has been ordered
Unless you have a permanent liquid propane gas line
installed, you will need to bring the black gas line under
the fire pit through the ventilation.
See
Figure B
.
For LP applications all you will have to do is connect the
LP regulator to your propane tank. Please ensure you
perform a leak test as items may have shifted during
transit.
Before you set the burner plate in place, check the air
mix fixture connected under the burner plate. The air
mix fixture has six holes that regulate the amount of air
that goes to the burner. When the nut is rotated forward
to cover the six holes, the burner is configured for liquid
propane. Make sure the air mix appears the way it does
in
Figure C
.
Perform a leak test before you replace the burner plate.
(See Step 3.)
Connect the black liquid propane hose to a gas cylinder.
Use a QCC-1 propane connector with a regulator. When
you connect the regulator to the tank valve, hand tighten
the black QCC-1 nut clockwise.
DO NOT
use a wrench to
tighten.
FIGURE A
FIGURE B
FIGURE C
*This diagram is for units with access doors, NOT units without
access doors. You may have to place a propane tank EXTERNALLY.
SIENNA