![Outdoor Lifestyles TWILIGHT-II-MDC Installation Manual Download Page 29](http://html.mh-extra.com/html/outdoor-lifestyles/twilight-ii-mdc/twilight-ii-mdc_installation-manual_1661237029.webp)
29
Outdoor Lifestyles by Hearth & Home Technologies • TWILIGHT-II-MDC Installation Manual • 2369-970 Rev. L • 8/19
APPLIANCE
HOOD
TOP HOOD
TOP OF
FIREPLACE
10-7/8 in.
CEILING OR OVERHANG
64-5/16 in.
MINIMUM CLEARANCE
TO VINYL SOFFIT,
CEILING OR OVERHANG.
35-5/16 in.
MINIMUM CLEARANCE TO
NON-VINYL SOFFIT, MANTEL,
CEILING OR OVERHANG.
STUD WALL
SOFFIT
HOUSEWRAP
INSULATION
HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.
SHEATHING,
COMBUSTIBLE
FIREPLACE
HEADER
INSULATED
FRAMING
STANDOFF
NON-COMBUSTIBLE
SHEATHING
FLASHING
HEADER
Figure 8.11 Exterior View
2-3/4 IN.
10-7/8 in.
HOOD
NON-COMBUSTIBLE
SHEATHING
6 in.
MAX.
NON-COMBUSTIBLE
FACING
THERE MUST BE NO GAP
BETWEEN BRICK LEDGE,
FACING MATERIAL AND
APPLIANCE FRONT.
SEAL GAPS WITH
NON-COMBUSTIBLE CAULK.
6 in. MAXMUM PROJECTION
FROM FACE OF FIREPLACE
BRICK LEDGE
NON-COMBUSTIBLE
SHEATHING (SUPPLIED)
COMBUSTIBLE
SHEATHING
HOUSEWRAP
REQUIRED
FLASHING
(SUPPLIED)
HOUSE
WRAP
EXHAUST
Figure 8.12 Exterior View
NOTE:
All finishing materials
on top of exterior
sheathing must be non-combustible for a minimum of
10-7/8 inches above and on both sides of the exterior
face of the appliance. This non-combustible finishing
material can be up to a maximum of 6 inches thick (6
inches maximum horizontal overhang) to allow for brick
and stone alcoves. See Figure 8.11 and Figure 8.12.
NOTE:
Combustible housewrap or building paper
MUST NOT
extend over the outside of non-combustible
sheathing, and
MAY
extend over the
flashing
header
behind non-combustible sheathing. Use high
temp caulk to seal between combustible sheathing
housewrap and non-combustible sheathing.