20
ft
m
•
Minimum height width offset/return
16
4.88
•
Maximum height
90
27.43
• Maximum chimney length between an offset
and return
20
6.1
•
Maximum distance between chimney
stabilizers
35
10.67
•
Double offset/return minimum height
24
7.32
•
Maximum unsupported chimney length
between the offset and return
6
1.83
• Maximum unsupported chimney height above
the fireplace
35
10.67
• Minimum overall straight height if fireplace is
freestanding
6.4
3.048
E. Chimney Requirements
When planning your fireplace location, the chimney con-
struction and necessary clearances must be considered.
The fireplace system and chimney components have
been tested to provide flexibility in construction. The fol-
lowing figures are the minimum distances from the base
of the fireplace.
•
Minimum overall straight height is 6 ft 4 in. If the
fireplace is freestanding and a minimum of 10 ft from
a combustible structure.
See Figure 6.1
• Chimney must extend 2 ft (.6 m) above any portion
of the roof within 10 ft (3 m) of the chimney. Refer to
Figure 8.7
Note:
A maximum of two pairs of offsets and returns may
be used.
Outdoor Lifestyles by Hearth & Home Technologies Inc.• 4072-137 Rev F • 11/25/13