background image

outdoorrooms.com

3

ASSEMBLY INSTRUCTIONS

 Do not discard any packaging until assembly is complete and unit is tested.

 Keep all included manuals in a safe place for future reference.

 Two people are recommended to remove table from packaging.

 Place table in desired location before installing control valve and gas

connection.

 

Exposed edges may be sharp, use leather gloves 

when removing packaging and handling the base.  

2.

!

!

CF-SPARKER

A. UNPACKING

B. CF-SPARKER INSTALLATION

CONTROL PANEL

WARNING

• Remove CF-SPARKER cap and hex nut.  Insert AAA battery 

(not included)

   with + end out.

• Unscrew mounting screws from control valve. Install CF-SPARKER 

on to control panel as shown below. Reconnect mounting screws and

control valve to control panel.

• Press in CF-SPARKER button to test your sparker.

CONTROL VALVE

Summary of Contents for Kinney KN-1224

Page 1: ...Installation Instructions for Kinney Fire Pit Table KN 1224 Kinney Fire Table outdoorrooms com...

Page 2: ...CRYSTAL FIRE PLUS BURNER WITHOUT CONSULTING THE CRYSTAL FIRE PLUS OWNER S MANUAL CONTENTS 1 About Your Fire Table 2 a Required Tools outdoorrooms com 42507 REV C 01 16 20 1 b Included With Your Fire P...

Page 3: ...c spark igniter installation 1 ABOUT YOUR FIRE TABLE Burner Cover 1 Fully Assembled Kinney Fire Table with CFP1224 Burner 1 A REQUIRED TOOLS B INCLUDED WITH YOUR FIRE PIT Bags of Glass Beads 2 Control...

Page 4: ...ol valve and gas connection Exposed edges may be sharp use leather gloves when removing packaging and handling the base 2 CF SPARKER A UNPACKING B CF SPARKER INSTALLATION CONTROL PANEL WARNING Remove...

Page 5: ...t included to the 3 8 male flare fitting on the valve USE TWO WRENCHES TO ENSURE A GAS TIGHT CONNECTION Run gas pipe up through the opening between the 2 base plates as shown in the image below A GAS...

Page 6: ...back of the CF SPARKER If an orange wire is present DO NOT USE IT The orange wire is for Direct Spark Ignition system only Test system by pushing the button on the igniter Consult the troubleshooting...

Page 7: ...Replace the access door ACCESS DOOR ATTENTION Over time the bearings in the door glides may require re greasing Any spray lubricant such as WD 40 may be used to lubricate drawer glides Perform annual...

Page 8: ...TE CRYSTAL FIRE PLUS BURNER WITHOUT INCLUDED GLASS BEADS OR OTHER APPROVED FIRE MEDIA WARNING DO NOT OPERATE CRYSTAL FIRE PLUS BURNER WITH BURNER COVER IN PLACE 4 MISCELLANEOUS Fully shut off gas supp...

Page 9: ...le surface C BURNER COVER STORAGE ATTENTION Use caution when removing and placing the burner cover as to not chip or damage the edge When not in use Burner cover can be conveniently stored within tabl...

Page 10: ...opane cylinder slowly open cylinder valve Press and hold sparker button Verify an audible and visible spark is present within the ignition wind guard Gently press and turn control knob to LOW IGNITION...

Page 11: ...ding lighting and operating instructions safety information and proper tightening of connections with two wrenches DO NOT ATTEMPT TO INSTALL CRYSTAL FIRE PLUS BURNER WITHOUT FIRST CONSULTING THE CRYST...

Page 12: ...s made with pride in the USA Warranty Fire pit tables are covered under a 1 year manufacturer s warranty Please visit http www outdoorrooms com product registration to register your product 14400 Sout...