B. THERMOCOUPLE INSTALLATION
outdoorrooms.com
9
C. ELECTRODE INSTALLATION
•
Plug both BLACK wires hanging from the burner into the back of the
CF-SPARKER. If an orange wire is present, DO NOT USE IT. The orange wire is
for Direct Spark Ignition system only.
•
Test system by pushing the button on the igniter. Consult the troubleshooting
section of the Crystal Fire® Plus owner’s manual if the spark is weak,
intermittent or not present.
SEE DETAIL B
SEE DETAIL A
SCALE 0.800
DETAIL A
SCALE 0.800
DETAIL B
•
Refer to Crystal Fire
®
Plus instruction manual for detailed attachment
of thermocouple.
•
Attach thermocouple to burner valve as shown below.