C. High Altitude Installations
U.L. Listed gas appliances are tested and approved with
-
out requiring changes for elevations from 0 to 2000 feet in
the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft,
it may be necessary to decrease the input rating by chang
-
ing the existing burner orifice to a smaller size. Input rate
should be reduced by 4% for each 1000 ft above a 2000
ft elevation in the U.S.A., or 10% for elevations between
2000 and 4500 ft in Canada. If the heating value of the gas
has been reduced, these rules do not apply. To identify the
proper orifice size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in
Canada), check with local authorities.
The Crystal Fire has been tested in accordance with IAS
US requirements for Outdoor Gas Fireplaces, Draft 4-96
and CSA requirement for Outdoor Gas Fireplaces, CR-97-
003 for Canada and has been listed by Underwriters Labo
-
ratory (UL) for installation and operation as described in
these installation and operating instructions.
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code
ANSI Z223.1 or CAN/CGA-B149.1, National Gas Instal
-
lation Code or CAN/CGA-B149.2, Propane Installation
Code.
B. BTU Specifications
MODEL:
CRYSTAL FIRE CF-20-LP
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Decorative Gas-Fired Outdoor Fireplace
STANDARD:
IAS US requirements for Outdoor
Gas Fireplaces, Draft 4-96 and CSA requirement for
Outdoor Gas Fireplaces, CR-97-003
A. Appliance Certification
1
Listing and Code Approvals
Model
Max Input BTUH
Orifice Size
Crystal Fire - LP
60,000
#43