OPERATING INSTRUCTIONS
IMPORTANT
Before operating your CAD-1224, ensure all gas connections are properly
tightened and thoroughly leak checked. Refer to the Crystal Fire manual for
information on proper leak checking and other critical safety information.
With the valve on the fire pit in the
OFF position, open the valve on the
propane tank or natural gas supply.
Double check to make sure there
are no gas leaks at the regulator
or inlet side of the valve. If leak is
detected, immediately shut off the
gas supply and wait 5 minutes to
allow gas to dissipate. Fix any leaks
before proceeding.
Press the sparker button and hold,
look and listen for spark between
electrode and grounding rod.
While depressing the sparker, open
the valve.
If burner does not light after 10 seconds,
close the valve and wait 5 minutes to
allow gas to dissipate before attempting
ignition again.
ATTENTION
Refer to the Crystal Fire manual
included with your burner for
more detailed information on
operation, maintenance, and
safety of your burner.
1. Press in sparker
3. Turn valve to ON
2. Look/listen for spark
5.
!
!
!
!