background image

Installation

900-0162-01-00 Rev A.vsd\Page-2\2014-01-24

©2014 OutBack Power Technologies.  All Rights Reserved.

RADIAN Series

16" (40.6 cm)

Plywood (Optional)

Wall Board

Wall 

Stud

Wall Bracket

Wall 

Stud

4.1" 

(10.4 cm)

5.0" 

(12.7 cm)

6.0" 

(15.2 cm)

8.0" 

(20.3 cm)

AC Circuit Breakers

1

GFDI

2
3
4

DC Terminals - Inverter

AC Terminals - Inverter

5

DC Circuit Breakers

6

PV Circuit Breakers

Charge Controller Terminals

7
8

Mechanical Interlock (Bypass)

9

10

Communication Ports

Auxiliary Terminals

11
12
13
14
15

AC OUT Bus Bar L1

16
17
18
19

AC OUT Bus Bar L2

GRID IN Bus Bar L1

GRID IN Bus Bar L2

GEN IN Bus Bar L1

GEN IN Bus Bar L2

AC Neutral

Ground

20

DC Positive (+) Plate (not used 
on GSLC175PV1-120/240)

PV Negative (–) Terminals

21
22

PV Positive (+) Bus Bars

DC Negative (–) Plate (GS-SBUS)

N
E
U

L1 L2

GRID

L1 L2

GEN

N
E
U

N
E
U

L1 L2

OUT

RELAY

AUX

+  -
12V 
AUX

Switch

INV

Remote

Battery 

Temp

FM80 #1 FM80 #2

MATE3

HUB 

10.3

GS8048A

GSLC175-PV-120/240

1

2

2

3

4

5

7

8

8

9

9

9

9

9

10

10

10

6

ON/OFF

INV

11

12

13

14

15

16

17

18

19

20

21

21

22

20

AC Wire Sizes and Torque Values

OutBack recommends that conductors be 

#6 AWG THHN copper, or larger, rated to 75°C 

(minimum) unless local code requires otherwise.

AWG

In-lb

#14 to #10

20

#8

25

#6 to #4

35

#3

35

#2

40

#1

50

1/0

50

mm

2

2.5 to 6

10

16 to 25

35

35

50

70

Nm

2.3

2.8

4.0

4.0

4.5

5.6

5.6

Wire Size

Torque

Torque Requirements

Plywood 

(Optional)

Wall Board

Wall 

Bracket

Wall Stud

N
E
U

L1 L2

GRID

L1 L2

GEN

N
E
U

N
E
U

L1 L2

OUT

RELAY
AUX

+  -
12V 
AUX

Switch

INV

Remote

Battery 

Temp

ON/OFF

INV

28.0" 

(71.1 cm)

16" (40.6 cm)

0.5" (1.3 cm)

0.5" (1.3 cm)

29.1" 

(74.0 cm)

45.0" 

(114.3 

cm)

13.7" 

(34.8 cm)

Inverter 
Bracket

8.75" 

(22 cm)

Circuit Breaker 

Stud

Torque

In-lb

Nm

M8

20

2.3

¼ - 20

35

4.0

5/16 - 18

50

5.6

3/8 - 16

225

25.4

DC Plates

Torque

In-lb

Nm

Upper holes (+)

Shunt Bolts (–) 

and GS-SBUS

Lower holes (+)

60

6.8

5.6

6.8

60

50

60

Minimum DC Cable based on 

the DC Circuit Breaker

Torque

In-lb

Nm

50

5.6

225

25.4

225

25.4

Circuit 

Breaker

Cable Size

125

1/0 (70 mm

2

)

175

2/0 (70 mm

2

)

250

4/0 (120 mm

2

)

35

4.0

80

#4 AWG (25 mm

2

)

35

4.0

60

#6 AWG (16 mm

2

)

Positive Battery Cable Connections

CAUTION:  

Equipment Damage 

When connecting cables 
from the Radian inverter 
to the battery terminals, 
make sure to observe 
the proper polarity. 
Connecting the cables 
incorrectly can damage 
or destroy the equipment 
and void the product 
warranty.

Ensure the mounting surface is strong enough to handle 3 times the total weight of all the components.  Add plywood or other 
reinforcing material as necessary to strengthen the surface.

Attach the wall bracket.  Center the mounting holes on the wall studs.  Use all 6 mounting screws to secure the bracket.

Lift the inverter so that the inverter bracket is above the wall bracket.

Lower the inverter so that the inverter bracket slips into the wall bracket. 

If GSLC is not used: 

Secure the inverter to the surface using a minimum of 1 wall screw (or appropriate hardware).  

If GSLC is used

: Unscrew the inverter bottom screws approximately ¼” (0.6 cm) to 3/16" (0.5 cm).

Align the GSLC along the bottom of the inverter.  Slide the bottom screws into the keyhole slots.

Mark the spots for the GSLC mounting feet.  (If necessary, remove the GSLC to install wall anchors.)  Install screws to secure the feet.    

Follow the appropriate instructions for installing other components.  Different mounting locations are available.

1

3
4

2

5
6
7
8

9

Keyhole Slots

1

2

3

4

5

6

7

The FLEXmax charge 
controller is mounted 
with the FW-CCB bracket.  
The FW-CCB2 allows two 
controllers side by side (using 
the forward holes to allow for 
conduit.)

The Radian has two sets of 
bracket positions.  The GSLC 
has one set.

NOTE:

The FLEXmax 

Extreme charge controller 
attaches directly to the wall, 
not the Radian system.  

It does not use 
OutBack brackets.

14.0" 

(35.6 cm)

12.0" 

(31.8 cm)

8

9

FN-DC

The Radian allows two locations 
for the MATE3 mounting bracket 
(FW-MB3).  

The Radian has one 
mounting location for the 
HUB product.  The GSLC 
also has one location. 

Left Side:

Right Side:

For GSLC door 
clearance, space 
systems 0.9" 
(3.2 cm) apart. 

When 

stacking 

multiple 

inverters:

N
E
U

L1 L2

GRID

L1 L2

GEN

N
E
U

N
E
U

L1 L2

OUT

1

Wiring to AC terminals is 
displayed on the Wiring page.

FN-DC wiring is displayed 
on the Wiring page.

Bottom 
Screws

19

Negative Battery Cable 

Connections 

Green

> 90% (blinks if charge parameters 

are met)

Color

Red

Yellow

Yellow

Yellow

80%

70% 

60% 

60% off, < 60% solid, < 50% blinks

Battery State of Charge

FN-DC LED Indicators

Bolt 3/8"

DC 

Positive 

(+) Plate

Battery 

Positive 

(+) Lug

Flat 

Washer

Nut

Lock 

Washer

Flat 

Washer

Shunt

Bolt 3/8"

Lock 

Washer

Flat 

Washer

Battery 

Negative 

(–) Lug

DC 

Negative (-) 

Plate 

(GS-SBUS)

GSLC175-PV-120/240

GSLC175PV1-120/240

DC Disconnect 

Stud

Battery 

Positive 

(+) Lug

FM80 

Positive (+) 

Terminal

Flat 

Washer

Nut

Lock 

Washer

FN-DC 

Positive (+) 

Sense 

Terminal

4

22

20

20

!