Installation Diagram:
Installation Instructions:
Use Tips:
1. This product is connected in series and should be installed in dry and dustproof environment.
2. Please select the products same as interface type of protected device.
3. IN is input terminal and OUT is the output terminal on surge protector. Input terminal connects outside line while
output terminal is connected to input of protected devices.
4. PE lines of surge protector must be reliable connection with the ground lead of lightning protection system. Ground
lead should be shortness, thickness and straightness (4 mm
2
< our recommendation < 50 mm
2
).
5. During the period of use, surge protector should be inspected regularly. If any failure occurs, it should be repaired or
replaced in time to ensure the safety of the protected equipment.
6. If device fails, do not disassemble or repair it by yourself. Please contact us timely.
NO
Step
1
Connect coax cable to IN (1)
2
Connect the coax cable of protected device to OUT (2)
3
Connect ground lead (3) to the grounding device