The degree of room compensation, the
compensation ratio, can be adjusted with
the COMP knob.

If the room temperature deviates from
the TMR/P set value, the TMR/P adjusts
the outgoing water temperature by a
ratio of the deviation set with the Comp
knob. These examples assume the
outdoor sensor is connected.

You can temporarily by-pass the timer program as follows:

Press and hold      until the desired state is displayed.
Repeating this procedure will change the state. The next
programmed time will switch the forced control state off.
If you wish to permanently use forced control, press 

again until the display shows              .

TIMER

TO SET THE DROP TIMES

TO SET THE TIME

VACATION FUNCTION

OPTIONAL EQUIPMENT

4

OUMAN can be equipped with a timer
that drops the room temperature for
desired periods (e.g., at night or on
weekends). The timer is easy to install
later.

Set the drop in the
temperature of the outgoing
water with this knob. The
numbers indicate the number
of degrees the temperature will be
dropped. General guide: a 4°C drop in the
water temperature corresponds to a 1°C drop in the
room temperature.

NOTE! If the room compensation unit TMR/P is in use,
double the temperature drop setting. This will take into
account the compensation effect of the TMR/P.

  Press    Display                Press     Note!

TO CLEAR THE PROGRAMS:

To clear the programs in the timer:

Press and hold       and       simultaneously.

1234567

PROG

1234567

The number indicates the amount
of free program positions.

Select the desired combination
of days when the temperature
drop should start.

Set the start  time for the
temperature drop: hour ...

... and minutes.
                  Acknowledge         .

Set the end time for the
temperature drop: hour ...

... and minutes.
                  Acknowledge         .

Now you can program a new temperature drop period.

Return to the normal state by pressing        twice.

Press   

Display 

Press 

Note!

1

2

34567

Set the hour.

Set the minutes. 

 Acknowledge      .    Time OK.

SUMMER/WINTER TIME DIFFERENCE:
Press and hold      .       The clock will automatically
                                       move ahead or back one  hour.

Summer time is being displayed

Select a day. 1=Mon,
2=Tue, 3=Wed, etc.

When the timer is switched on, all the symbols in the
display will blink. Follow the procedure shown below.

Meaning of symbols:

 Press once               Press repeatedly until the

                                                                          desired state is displayed

Press  

Display 

Press 

Note!

Set the length of the vacation
period
(1... 99 days).
Set the temperature state during
the vacation.
1 = temperature drop
0 = normal temperature
                  Acknowledge       .

When the timer arrives at the vacation function time, the
          symbol will be displayed.
If you do not press acknowledgement       , the timer will
return to the basic state. You can start programming
again.

Set the number of days after
which the vacation function
should start (0... 14 days).

The vacation function lets you program a temperature
drop period that begins immediately or later (0 ...14
days). The temperature drop period can last  1... 99
days.

The display now shows the correct time and the colon
 between the numbers is blinking. The programmed
temperature drop period is darkened.

0 = normal
temperature (the
temperature is not
dropped)

24

12

6

18

21

3

15

9

1 =  The temperature is dropped

TO BROWSE A PROGRAM:
When the display shows PROG, you can browse through

a program in the timer by repeatedly pressing       .

TO ADD A PROGRAM:
The timer must be in the PROG state. Press

until                       is displayed, then begin
programming a new temperature drop period.

1234567

1

4

Manufacturer:

OUMAN OY

KEMPELE, FINLAND

Select the desired room temperature with the TMR/P
knob. 21°C is in the middle. Each step of the scale equals
1°C. If the room temperature deviates from the set
temperature, the TMR/P automatically adjusts the
outgoing water temperature.

Example 1. 

The COMP knob is in position 4. If the room

temperature drops 1,5°C, the TMR/P will raise the
outgoing water temperature by 4 x 1,5 = 6°C.

Example 2.

 The COMP knob is in position 2. If the room

temperature rises 4°C, the TMR/P will lower the
outgoing water temperature by 2 x 4 = 8°C.

ONLY ROOM COMPENSATION

OUMAN can be connected as a room-controlled outgoing
water controller. (Disconnect the outdoor sensor.) Set
the room temperature with the TMR/P knob. If the delay
before the radiator temperature reacts to a change in
room temperature is too long, increase the COMP ratio.

1

4

2

1

3

3

3

3

2

2

2

2

4

4

1

2

1

3

3

2

4

2

3

3

2

1

3

4

2

3

3

0

1

4

4

0

2

2

0

p

The OUMAN EH 80 can be equipped with an optional room
compensation unit, TMR/P. It improves temperature control
in special conditions such as:

*   windy weather (the house  tends to get cooler)
*   the house is warmed by
a fireplace, brick oven, etc.
*   the house has large
windows on the south side,
and the house gets warm
on sunny spring days
regardless of cold   weather.

Install the TMR/P in a
central place in the  house.

ROOM COMPENSATION TMR/P

PROG

FORCED CONTROL

KS/80

E H - 8 0