INSTALLATION OF CONDENSATE PIPE
• The condensate pipe should keep an inclination angle
of 5 to 10 ° to facilitate the drainage of the condensate
water.
• The joints of the condensate pipe should be insulated to
prevent condensing, as shown on opposite image.
• There is a condensate outlet on both left and right sides
of the unit. Once one is confirmed to be used, the other
should be clogged by a rubber plug, bundled by the
binding wire and insulated by the insulation material to
avoid water leakage.
• The outlet on the right side is defaulted to be clogged with a plug.
CAUTION
No water leakage is allowed on the joint of the condensate pipe.
Pipe lid
Insulating layer for
condensate pipe