HEATER OPERATION

1.  Plug in heater. 

2.  Use heat “HIGH / LOW” switch 
 to 

select 

heat 

desired. 

3.   Rotate thermostat knob full clockwise. 
 

Indicator light on.

 
4.   Use fan “AUTO / ON” switch to select fan operation.  
 

“AUTO” – Fan controlled by thermostat.  

 

“ON” – Continuous fan operation.

TO TURN HEATER OFF 

Rotate thermostat knob full counter- clockwise.  

FAN ONLY OPERATION (No heat)

1.  Rotate thermostat knob full counter- clockwise.  
 

Indicator light off.

2.   Place fan “AUTO / ON” switch in “ON” position.  
 

Fan runs continuously,  heat remains off.

Figure 3

Plug: 

IMPORTANT

This heater is equipped with a Factory Installed

Manual Reset Limit

:  Located on the back of the heater, 

the manual reset limit will automatically turn the heater off 
if an overheat condition exists. 

To reset

 – Allow the heater 

to cool - Then, push in the button until it snaps. The heater 
should then operate normally.

LOCATE HEATERS PROPERLY

FLOOR MOUNTING:

Place heater on fl oor, plug into proper wall outlet and adjust 
heater to direct airfl ow.

WALL MOUNTING:

Heaters may be mounted for either horizontal or vertical air 
discharge.

Maximum mounting height:
Vertical air fl ow – 15 feet (4.57 m)
Horizontal air fl ow – 8 feet (2.44 m)

NOTE 

- Wall must be able to support the weight 

of the heater 33 lbs (15 kg).

Figure 1

         

Minimum Clearance:

Take heater out of the mounting stand.

Attach the stand to the wall structural members with four 
(4) ¼ in. dia. X 1 ½ in. long lag bolts 
(Not provided).

Put heater back into stand (put rubber washers between 
stand and heater brackets) and start two (2) knobs.

Plug into proper wall outlet, adjust to direct airfl ow and 
tighten two (2) knobs.

CEILING MOUNTING:

Heaters may be mounted for either horizontal 
or vertical air discharge.

Maximum mounting height:
Vertical air fl ow – 15 feet (4.57 m)
Horizontal air fl ow – 8 feet (2.44 m)

NOTE

 - Ceiling must be able to support the weight 

of the heater 33 lbs (15 kg).

Figure 2

Minimum Clearance:

Take heater out of the mounting stand.

Attach the stand to the ceiling structural members with 
four (4) ¼ in. dia. X 1 ½ in. long lag bolts (Not provided).  

DO NOT USE KEYHOLE SLOTS – USE CIRCULAR 
HOLES ONLY.

Put heater back into stand (put rubber washers between 
stand and heater brackets) and start two (2) knobs.

Plug into proper wall outlet, adjust to direct airfl ow 
and tighten two (2) knobs.