background image

swing  freely.  The  AFB  slightly  dampens  the  free  swing,  thereby  making  a  close  approximation  of  the  forearm’s
physiological movement behaviour possible. 
The product does not consume electrical energy during the free swing. A short muscle signal to flex the product
ends the free swing.

Humeral rotation feature

The humeral rotation feature is an upper arm rotation joint with bilateral stops. It is used for rotation of the forearm.
The resistance of the humeral rotation feature can be changed using the adjusting screw.

Easy Plug

1. No function
2. Electrode
3. Electrode
4. Optional switch

The Easy Plug feature makes it simple to wire myoelectric prostheses.
The connecting cables of the electrodes and an optional switch are connected to the Easy Plug. Its interior cable
routing minimises the risk of cable breaks.

Forearm cable

The  forearm  cable  establishes  the  electrical  connection  between  the  product,
electric wrist rotator and System Electric Hand or System Electric Greifer.
On delivery the forearm cable is rolled up in the forearm of the elbow joint. After
the forearm has been cut to its final length, the forearm cable can be pulled out.

INFORMATION

Do not pull out cables before cutting the forearm to length.

Lock

Releasing and locking the elbow joint is automated according to operating situations, the applied load and the con­
trol signal generated by the patient by means of the electronically controlled locking drive.
The product has a load capacity of up to 230 N in the locked state with a forearm lever length of 305 mm. The lock
will slip under higher loads.

Mechanical release

With  the  product  switched  off  or  when  the  battery  is  drained,  the  elbow  can  be  manually  unlocked  and  locked
again  with  a  slight  pull  on  the  unlock  cable.  In  this  way,  the  forearm  can  be  brought  into  the  desired  position.
Mechanical release can also take place under load. 

4

Product description

DynamicArm 12K100N

Summary of Contents for DynamicArm 12K100N

Page 1: ...DynamicArm 12K100N Instructions for use qualified personnel 3...

Page 2: ...PT INFORMA O Adicionalmente ao manual de utiliza o impresso encontra se inclu do um CD com mais idiomas consultar a contracapa A pedido poss vel encomendar gratuitamente um exemplar impresso do manual...

Page 3: ...ally controlled elbow joint driven by an electric motor It helps the wearer perform everyday tasks in combination with other prosthetic components see Page 5 A Li Ion battery integrated into the produ...

Page 4: ...shes the electrical connection between the product electric wrist rotator and System Electric Hand or System Electric Greifer On delivery the forearm cable is rolled up in the forearm of the elbow joi...

Page 5: ...anatomical replacement for the elbow joint and forearm 3 2 Conditions of use The product is suitable for patients with unilateral or bilateral upper arm amputations The product is intended exclusively...

Page 6: ...WARNING Use of the product while operating a vehicle or machinery Risk of accident due to unexpected behaviour of the product Risk of injury due to faulty control or malfunction of the product Applica...

Page 7: ...Improper use Injury due to loss of product functionality Instruct the patient in the proper use of the product CAUTION Manual unlocking of elbow lock under load Injury by release of elbow lock under...

Page 8: ...erminal device before use so that a slight turn cannot disconnect the terminal device from the prosthesis CAUTION Incorrect donning and doffing of the product Injuries The product should always be fle...

Page 9: ...152 instructions for use qualified per sonnel 1 pc 646D229 instructions for use user 1 pc 646T333 instructions for use qualified per sonnel 1 pc 646D644 service pass Accessories 1 pc strap clamp for U...

Page 10: ...esis should be approx 1 cm shorter than the sound arm 2 Cut the forearm using a vibrating saw 3 Sand all sides of the cut edge at a right angle Smooth inner and outer sanded edges Round the inside edg...

Page 11: ...efully and proceed exactly in the order described INFORMATION Read the relevant material safety data sheets before processing the 636K18 Orthocryl sealing resin compact adhesive and the 617H14 hardene...

Page 12: ...m length For forearm lengths from 225 mm to 213 mm with 10S17 electric wrist rotator Make sure the 10S17 electric wrist rotator dummy is pushed over the cable protector cap This ensures correct axial...

Page 13: ...et head screw 3 Or pull out the lamination ring cover on its own 4 Remove the cable protector cap using the hook 5 The cables are rolled up inside the cable protector cap When removing the cable prote...

Page 14: ...electric wrist rotator Proceed as described above to cut to length and glue in the lamination ring INFORMATION If the foam disc has been glued into place the cables can be pulled out carefully throug...

Page 15: ...de housing with the connected cables into the greased lamination ring It has to engage completely 2 The circuit board and the edge of the lamination ring must be parallel to each other 3 The electrode...

Page 16: ...socket Make sure the friction adjustment screw and lamin ation ring thread recess are applied opposite to each other 3 Set the AFB dial to minimum compensation force 4 Extend the elbow and lock it wit...

Page 17: ...into neutral position no outward or inward rotation 2 Affix the cable guide to the socket with cap screws centred in relation to the strap clamp and approx 30 mm away from the lamination ring CAUTION...

Page 18: ...er arm section of the prosthesis while testing the joint function 4 Position 1 Low compensation that allows natural free swing of the arm while walking Position 2 Compensation increases progressively...

Page 19: ...the three pole connectors is marked with a coloured dot 5 If the two three pole connectors are interchanged when connecting them to the two contacts no func tion of the System Electric Hand or System...

Page 20: ...requency range of 50 60 Hz INFORMATION Please note the corresponding instructions for use of the battery charger 7 1 1 Charging process WARNING Charging the prosthesis without taking it off Risk of el...

Page 21: ...arging the battery We recommend charging the product once a day when used by the patient on a daily basis The battery should be charged for at least 3 hours prior to initial use Note the permissible t...

Page 22: ...s Risk of injury due to sudden flexion of the prosthesis Switch off the prosthesis before donning or doffing The prosthesis must always be flexed for donning and doffing 7 4 Switching modes 7 4 1 Swit...

Page 23: ...stem Electric Gre ifer Control Two electrodes and 4 stage control element Indication For patients with two strong muscle signals Control type Proportional Switching between the components takes place...

Page 24: ...with co contraction Switching to the hand Switching to the elbow joint Switching back Automatically switching back to the hand component takes place five seconds after relaxing the muscles DynamicArm...

Page 25: ...s controlled by the linear control element Switching to the elbow joint Flexion Pull on the linear control element Extension Release of the linear control element 8 Cleaning and Care 1 Clean the produ...

Page 26: ...mation that applies exclusively to specific countries is written in the official language of the respective country of use in this chapter This device complies with part 15 of the FCC Rules Operation...

Page 27: ...ngton Ontario Canada Phone 1 800 665 3327 Caution Federal law USA restricts this device to sale by or on the order of a practitioner licensed by law of the State in which he she practices to use or or...

Page 28: ...Disposal that is not in accordance with the regulations of your country may have a detri mental impact on health and the environment Please observe the instructions of your national authority pertain...

Page 29: ...is present Function is present Very high high low very low Decreasing bat tery charge level No function Function is present Function is present 6 x low Battery charger was connected during opera tion...

Page 30: ...30 DynamicArm 12K100N...

Page 31: ...31 DynamicArm 12K100N...

Page 32: ...ersion SB_2016 10 21 FM483 SB_210x297 Otto Bock Healthcare Products GmbH Brehmstra e 16 1110 Wien Austria T 43 1 523 37 86 F 43 1 523 22 64 info austria ottobock com www ottobock com Ottobock 647G152...

Reviews: