Otto Bock AxonArm Ergo 12K501 Instructions For Use Manual Download Page 18

(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en com­
promettre le fonctionnement.

Caution: Exposure to Radio Frequency Radiation.

The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit
RF field in excess of Health Canada limits for the general population.

Caution: Federal law (USA) restricts this device to sale by or on the order of a practitioner licensed by law of the
State in which he/she practices to use or order the use of the device.

9 Technical data

Ambient conditions

Storage (with and without packaging)

+5 °C/+41 °F to +40 °C/+104 °F
Max. 85%relative humidity, non-condensing

Transport (with and without packaging)

-20 °C/-4 °F to +60 °C/+140 °F
Max. 90% relative humidity, non-condensing

Operation

-5 °C/+23 °F to +45 °C/+113 °F
Max. 95% relative humidity, non-condensing

Charging the battery

+5 °C/+41 °F to +40 °C/+104 °F
Max. 85%relative humidity, non-condensing

General

AxonArm Ergo

Reference number

12K501=*

Dimensions [mm]

Approx. 345 mm x d55 mm to d80 mm (arm extended)

Weight without Axon-Bus terminal device [g]

Approx. 840 

Forearm length as delivered [mm]

305 

Minimum adjustable forearm length [mm]

187

Flexion angle

15 °–145°

Maximum  vertical  load  with  locked  elbow  joint  and  a
forearm length of 305 mm [kg]

23

Expected  lifetime  given  compliance  with  service  inter­
vals [years]

Operating time with full charge

Approx. 2500 gripping and locking cycles or approx.

8 hours

Rechargeable battery lifetime [years]

2

Charging time [h]

3.5

10 Appendices

10.1 Symbols Used

Declaration of conformity according to the applicable European directives

In some jurisdictions it is not permissible to dispose of these products with unsorted household
waste. Disposal that is not in accordance with the regulations of your country may have a detri­
mental  impact  on  health  and  the  environment.  Please  observe  the  instructions  of  your  national
authority pertaining to return and collection.

Serial number (YYYY WW NNN)
YYYY – year of manufacture
WW – week of manufacture
NNN – sequential number

Medical device

18

Technical data

AxonArm Ergo 12K501=*

Summary of Contents for AxonArm Ergo 12K501

Page 1: ...Instructions for use qualified personnel 3 AxonArm Ergo 12K501...

Page 2: ...1 2 2 AxonArm Ergo 12K501...

Page 3: ...6 5 12 Adjusting the Humeral Rotation Feature 6 6 14 Installing the Pull Cable 6 7 14 Checking the Symmetry 6 8 14 Handling 7 15 Charging the Battery 7 1 15 Charging Receptacle 7 2 15 Determining the...

Page 4: ...The movements of the Axon Bus gripping component are becoming increasingly slower 10 2 4 19 Axon 10 3 19 4 AxonArm Ergo 12K501 Table of contents...

Page 5: ...of the elbow joint The Automatic Forearm Balance provides for harmonious movement control free swing and reduction of energy consumption It stores the energy that is released when the arm is extended...

Page 6: ...gs 3 2 Conditions of use The product is designed for use by unilateral or bilateral amputees The product is intended exclusively for use on adults The product was developed for everyday use and must n...

Page 7: ...ed theft prevention systems at the entrance exit of stores metal detectors body scanners for persons e g in airports or other sources of strong magnetic and electric al interference e g high voltage l...

Page 8: ...high voltage lines transmitters transformer stations computer tomographs magnetic resonance tomo graphs etc Allow the patient to rest during the adjustment of the electrodes otherwise muscle fatigue w...

Page 9: ...hetic glove e g 8S500 R L AxonSkin Natural when 8E500 Michelangelo hand is used Additional MyoBock components such as suction socket electrode electrode cable pull in tube and tube valve for suction s...

Page 10: ...long co contraction on channels 1 and 2 of the AxonMaster releases or locks the lock A short co contraction switches the gripping mode of the gripper A pulse on channel 3 of the AxonMaster releases or...

Page 11: ...Reduction in mechanical strength due to thread misalignment The circuit board and the edge of the lamination ring must be parallel to each other Left picture The EasyPlug has been snapped in properly...

Page 12: ...isted 7 Slide the strap clamp under the lamination ring 8 Screw the strap clamp in 6 5 Setting the Preflexion The level of AFB compensation flexion assistance can be adjusted and adapted to the weight...

Page 13: ...e forearm or the upper arm socket due to released lock The Axon Bus prosthethic system must always be flexed for donning and doffing The Axon Bus prosthethic system must be stored in flexed condition...

Page 14: ...rntable friction is easily adjusted by turning of the external adjustment screw using a coin or similar object 6 7 Installing the Pull Cable CAUTION Removing the pull cable Injury due to malfunction o...

Page 15: ...ing Receptacle The charging receptacle Fig 1 item 2 has the following functions Contacts for charging the battery LED display to indicate the current battery charge level LED display for providing fee...

Page 16: ...1x short 1x long Beep Pulsating Turn the Axon Bus pros thesis solution on Push the button for one to four seconds Turn the Axon Bus pros thesis solution off Push the button for more than one second C...

Page 17: ...that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to pr...

Page 18: ...ing General AxonArm Ergo Reference number 12K501 Dimensions mm Approx 345 mm x d55 mm to d80 mm arm extended Weight without Axon Bus terminal device g Approx 840 Forearm length as delivered mm 305 Min...

Page 19: ...ds Probable cause The Axon Bus prosthetic system is overheated Remedy 1 Allow the Axon Bus prosthetic system to cool for a few minutes 2 Do not use the Axon Bus prosthetic system at high ambient tempe...

Page 20: ...sion SB_2021 02 FM483 SB_210x297 Otto Bock Healthcare Products GmbH Brehmstra e 16 1110 Wien Austria T 43 1 523 37 86 F 43 1 523 22 64 info austria ottobock com www ottobock com Ottobock 647G790 0 en_...