INS90011 REV041709
571PN3
3.
Using the Lamp with battery power:
a.
See diagram (G) as needed.
b.
Battery operation should be attempted only when the
battery has a full charge or close to a full charge.
c.
Disconnect the AC Adapter (H) from the 9V DC
connector (E).
d.
Move the AC/ DC switch to the DC position.
e.
Rotate shade to an open position and press on/off
button (F).
f.
If the AC/ DC switch is moved to the AC position the
lamp will turn off, this is normal.
4. Lamp Adjustments:
Height
a.
To adjust shade height, press button (D) to release the
shade latch.
b.
Gently raise shade all the way up (about 3”), it will latch
in place.
c.
To lower the shade, first hold the shade in position then
press the shade release button (D) and lower it all the
way down.
Shade Tension
a.
Use a coin in slot (M) of the tension joint to tighten or
loosen the shade tension. Tighten only enough to keep the
shade in place. Overtightening will damage the lamp.
TUBE INSERTION / REMOVAL
1.
Turn lamp off by pressing power switch (F).
2.
Disconnect lamp from wall power, if connected.
3.
If the lamp has been in use allow it to cool approximately
5 minutes before proceeding.
4.
Remove the diffuser (A) by holding the shade (C) and pull down
on the end of the diffuser. The diffuser is held in place at 4 places
and snaps in or out of holding slots. Squeezing the shade slightly
at the slot locations will aid in removal.
5.
Remove tube (B) from packing and install into lamp socket,
inside shade (C), by aligning tube base with socket then push
firmly until it snaps into place. Do not twist or turn the tube. Give
a gentle pull on the tube to confirm it is being held by the socket.
6.
Reattach diffuser (A) to shade (C) by aligning the holding tabs
with the holding slots and pressing to snap into place.
BATTERY-MAINTENANCE INSTRUCTIONS
a. Battery Care:
Rechargeable Sealed Lead Acid (SLA) batteries require proper
care and use to ensure maximum life (number of charges and
duration of use). Fully charge your SLA battery before using it
the first time. Do not store your battery for more than 4-6 weeks
without charging. Normally, a SLA battery will self-discharge
1% per day even when not in use.
b. Battery Capacity:
Your lamp is supplied with a 5Ah (ampere-hour) SLA battery
that will initially give 3 or more hours of use. As the battery ages,
hours of use will normally decrease. A fully charged battery that
will not keep the lamp lit continuously for more than 1 hour is
considered depleted and should be replaced.
Replacement batteries are available from OttLite as well as other
sources. However, a battery of less than 5Ah capacity will give
fewer hours of use.
SLA batteries are the best choice for long use time, rechargeabil-
ity, and economy however they take a long time to charge to full
capacity. To ensure a full capacity charge, let your battery charge
overnight (12 to 16 hours). Short use times (less than an hour) and
short charge times (1 to 12 hours) will not hurt your battery for a
few operations, but always fully charge the battery when possible.
c.
Power Indicator light (N): The Power Indicator light indicates
that the lamp is connected to AC power (wall outlet); a connected
battery will be charging when the light is RED. To ensure optimal
capacity, charge the battery for 12 to 16 hours after use.
BATTERY CAUTIONS:
CAUTION – HIGH ENERGY STORAGE
• DO NOT ALLOW THE BATTERY TERMINALS TO BE SHORTED:
1) DO NOT ALLOW CONDUCTIVE MATERIALS TO CONTACT TERMINALS.
2) BATTERY DOOR MUST BE INSTALLED DURING USE AND CHARGING.
3) DO NOT EXPOSE TO WATER.
• BATTERY CONTAINS STRONG ELECTROLYTE.
• DO NOT APPLY UNDUE FORCE, DROP, OR STRIKE BATTERY.
• DO NOT ATTEMPT TO DISASSEMBLE OR MAKE MODIFICATIONS TO
BATTERY.
• IF BATTERY IS DAMAGED AND ELECTROLYTE CONTACTS SKIN OR
CLOTHING, WASH IMMEDIATELY WITH WATER.
• IF ELECTROLYTE GETS INTO EYES, FLUSH WITH CLEAN WATER AND
SEEK MEDICAL ATTENTION IMMEDIATELY.
• WHEN INSERTING THE BATTERY INTO THIS PRODUCT, CORRECT
POLARITY MUST BE OBSERVED. REVERSING OF CORRECT POLARITY
CAN CAUSE LEAKAGE OF ELECTROLYTE OR EXPLOSION.
• DO NOT EXPOSE BATTERY TO HEAT OR FLAME.
The battery should be fully charged after any long period of
non use to ensure long life. Maximum battery life is achieved by
recharging the battery before a complete discharge is reached
and before prolonged storage.
BATTERY REPLACEMENT:
CAUTION – HIGH ENERGY STORAGE
CUSTOMER: IF YOU HAVE ANY CONCERN OR QUESTION IN
REFERENCE TO INSTALLING THE BATTERY, PLEASE SEEK
QUALIFIED ASSISTANCE. FAILURE TO DO SO CAN RESULT
IN DAMAGE OR INJURY.
1.
Remove the battery door by loosening the retention screws (K)
and pull the top of the door away from the lamp.
2.
Gently work the battery (L) out the lamp making sure the leads
(J) do not catch on anything.
3.
Remove each lead by grasping firmly on the insulated end and
pull the lead away from the terminal using a slight side-to-side
rocking motion.
4.
Attach the leads to the new battery by grasping firmly on the
insulated end, align the lead to the terminal, then push the end
fully onto the terminal. Connect the RED lead to the positive (+)
terminal and the BLACK lead to the negative (-) terminal.
5.
Replace the battery in the lamp. Confirm lead wires are
positioned to prevent pinching of wires. Slide the battery fully
into the lamp.
6.
Replace the battery door and secure with the retention screws
(K) to hold the door in place.
RECYCLING OF BATTERY:
The product you have purchased contains a rechargeable battery.
This battery is recyclable. At the end of its useful life, under various
state and local laws, it may be illegal to dispose of this battery in
the municipal waste system. Please check with your waste officials
for details on recycling or proper disposal.
www.recycle.com
Please note that in operation, OttLite
®
tubes are not dimmable.
Enjoy your OttLite
®
Rechargeable Task Lamp!
This lighting system is designed for use with OttLite
®
tubes
only (model number T57J3C / T15003). Use of other products
voids the warranty and may result in damage to the lighting
system.