1
115V 1Ph 60Hz
14
1
208/230V 1Ph 60Hz
8.3/7.5
300 / 375
91.4 / 114
500 / 600
152 / 183
800 / 975
244 / 297
2
208/230V 1Ph 60Hz
13.7/12.4
175 / 225
53.3 / 68.6
300 / 375
91.4 / 114
475 / 575
145 / 175
750 / 925
229 / 282
3
208/230V 1Ph 60Hz
15.5/14
250 / 325
76.2 / 99.1
425 / 525
130 / 160
675 / 825
206 / 251
3
208/230V 3Ph 60Hz
9.7/8.6
300 / 375
91.4 / 114
500 / 625
152 / 191
800 / 975
244 / 297
1000 / 1000
305 / 305
3*
380V 3Ph 60Hz
4.6
3*
460V 3Ph 60Hz
4.3
5
230V 1Ph 60Hz
23
5
208/230V 3Ph 60Hz
15.1/13.4
200 / 250
61 / 76.2
300 / 400
91.4 / 122
500 / 625
152 / 191
5*
380V 3Ph 60Hz
7.6
5*
460V 3Ph 60Hz
7.2
5*
575V 3Ph 60Hz
5.5
1
220V 1Ph 50Hz
8.3
2
220V 1Ph 50Hz
12.6
3
220V 1Ph 50Hz
13.5
3*
380/415V 3Ph 50Hz
4
1000 / 1000
305 / 305
5*
380/415V 3Ph 50Hz
7
775 / 1000
236 / 305
6AWG / 16mm²
91.44
Electrical Rating
HP
Feet
Meters
152.4
500
Meters
10AWG / 6mm²
8AWG / 10mm²
Running
Amps
Feet
Meters
12AWG / 4mm²
Feet
Feet
Meters
150
45.72
250
76.2
1000
304.8
304.8
300
220.98
304.8
304.8
200
325
1000
925
725
304.8
281.94
Concept 3 Maximum Cable Lengths
99.06
325
160.02
325
(*Cable for these systems may be available in longer lengths, call the factory to inquire)
1000
350
525
160.02
167.64
259.08
525
60Hz.
50Hz.
!IMPORTANT!
Cable lengths are based on a 5% cable voltage drop between the PCC and the motor unit.
It is important to consider the total voltage drop is 5%
including
the branch circuit to the PCC.
550
850
60.96
99.06
1000
1000
Maintenance
Your Otterbine aerator requires periodic maintenance:
A. Once a year, disconnect the unit from the power source and physically inspect the aerator and
underwater cable for any cuts, cracks or breaks. These may cause oil leaks and/or electrical shorts. Inspect and
clean the pumping chamber components and screen.
B. After every three running seasons, a simple oil change is necessary to keep your unit running
smoothly. Otterbine oil must be used for this oil change. Please contact your local Otterbine distributor to
order a maintenance kit, p/n 12-0077.
WARNING: Do not overfill motor housing with oil, may cause damage.
When a unit is properly cared for, it will give you years of trouble free service. If a problem does arise, please
contact your Otterbine distributor or the factory directly at 1-800-AER8TER.
37
Summary of Contents for Concept3
Page 6: ...115 Volt 1 Phase 60 Hertz Schematic 208 230 Volt 1 Phase 60 Hertz Schematic 6...
Page 7: ...208 230 Volt 3 Phase 60 Hertz Schematic 460 Volt 3 Phase 60 Hertz Schematic 7...
Page 8: ...220 Volt 1 Phase 50 Hertz Schematic 380 415 Volt 3 Phase 50 Hertz Schematic 8...
Page 30: ...15 18 17 2 8 26 5 7 14 16 10 1 11 4 3 9 13 19 6 30...