background image

English

Mounting instructions

Bubble pot

EPS 50

OTT Hydromet GmbH
P.O. Box 2140 

 

87411 Kempten

Ludwigstrasse 16 

 

87437 Kempten

Phone++49 831 5617-0

Fax++49 831 5617-209
E-mail: [email protected]

Internet: http://www.ott.com

Dokumentnummer

55.510.048.B.E 03-0411
Subject to technical changes!

Release the conical nut slightly and adjust the bubble pot horizontally (both

axis) and with the direction of the flow.

Tighten the conical nut again.

Maintenance

Regularly check the bubble pot – at least once a year – if there is any debris

and if it is still correctly aligned. If there are lots of particles or weeds in the

water you have to check more frequently.

For cleaning you have to remove the three Phillips screws and the base plate at

the bottom of the bubble pot. For this the bubble pot can, but must not necessa-

rily be detached. Perhaps you have to slightly release the conical nut and to

turn the basin by 180°. After cleaning the bubble pot has to be adjusted again

to the direction of the flow. Attention: the bubble in pressure must be built up

again; see user instruction for Nimbus!

Base plate

Basin

Conical nut

Phillips

screws

Abb. 5: Cleaning of bubble pot

If the bubble pot is completely detached for

cleaning the bubble tube must be cut by 1

cm before it is connected again.

Adjustment range: 

±

15 

°

Conical nut

Picture 4: Adjust bubble pot

max. tolerance of adjustment 

is +/- 5°!