OTS Aquacom MK2-DCI User Manual Download Page 10

SECTION 4: BATTERIES

The MK2-DCI Two-Diver Air Intercom can be powered by two 6-volt heavy duty
alkaline batteries, rechargeable 6-volt batteries (Ocean Technology Systems’ model
no. RB-6), or a 12-volt alternate source. To recharge RB-6 batteries, obtain an
RCS-13 universal smart charger from OTS or your local OTS dealer.

The following are options for the desired power source:

1) LANTERN BATTERIES: The MK2-DCI is designed to use two 6-volt spring-

connector–type batteries. We recommend the use of 6-volt alkaline batteries,
to achieve optimum performance. Eveready or Duracell alkaline batteries pro-
vide the best results for most diving operations. You can use standard 6-volt
lantern batteries with spring connectors as well; however, battery life will be
greatly reduced, and you will notice a substantial power drop when transmit-
ting.

INSTALLATION OF 6-VOLT BATTERIES: Locate and loosen the four screws
located on the front panel (Fig. 1, #19). These screws are captive and will not
come off the front panel. Remove front panel from housing. Remove cotter pin
from battery strap (Fig. 4, #3). Remove battery strap from battery housing
(Fig. 4, #2). Insert both 6-volt, spring-type lantern batteries, springs facing
toward battery PC board (Fig. 4, #4). Verify that the batteries are secure on the
bottom of the housing and the backs are being held by the back plate. You will
notice the batteries can be installed with springs in any direction on the PC
board (Fig. 5). After batteries are installed, replace the battery strap and cotter
pin, dress the wires so they are not pinched when you put the front panel back
in place, replace the panel, and tighten the four screws (do not overtighten).

2) 6-VOLT RECHARGEABLE BATTERY (RB-6V): When utilizing the optional

RB-6V sealed lead acid battery, you will attain the maximum performance of a
self-contained battery (two are required).

Note: The batteries you receive may have upgraded specifications from what
is stated in this manual. Due to advancing battery technologies, we continu-
ally upgrade our batteries and chargers. Contact OTS or your OTS dealer to
find out the latest available battery and charger.

Install the RB-6V batteries per the instructions found on page 9, “INSTALLA-
TION OF 6-VOLT BATTERIES.”

The RCS-13 universal smart charger is available for rapid charging of RB-6
rechargeable batteries. It closely monitors the batteries’ voltage level to charge
them only as necessary. Power cords compatible with the electrical outlets of
various regions of the world are available for use with the RCS-13.

7

Summary of Contents for Aquacom MK2-DCI

Page 1: ...User s Guide Technology in Depth Two or One Diver Intercom AQUACOM MK2 DCI...

Page 2: ...es all risk and liability whatsoever in connection therewith Neither Seller nor Manufacturer shall be liable either in tort or in contract for any loss or damage direct incidental or consequential ari...

Page 3: ...s 3 3 1 System Components 3 3 2 Two Wire Mode 4 3 3 Four Wire Mode 5 Section 4 Batteries 7 Section 5 Helpful Hints 10 Limited Warranty 13 Illustrations Figure 1 MK2 DCI Two Diver Air Intercom 4 Figure...

Page 4: ...contained Two or One Diver Air Intercom pro viding clear communications between the operator and diver s The MK2 DCI offers two or four wire communications This manual will cover specifications operat...

Page 5: ...kaline ID 9150 or an external 12 volt source optional 6 volt rechargeable batteries Power Output 20 watts Frequency Response 600 to 12 000 Hz Cabinet Material ABS plastic Front Panel 1 8 aluminum chem...

Page 6: ...0 Earphone Diver 1 earphone connection banana or bare wire style 11 Microphone Diver 1 microphone connection banana or bare wire style 12 Volume Diver 1 tender to diver volume control 13 Microphone Di...

Page 7: ...e surface unit Fig 2 If a four wire cable is used two wires are normally twisted together for one side of the microphone binding post and the remaining two wires twisted together for the other microph...

Page 8: ...ender and up to five divers or any combination of recompression chambers or diving bells The four wire mode will give you optimum performance and intelli gibility by the MK2 DCI Using this method ever...

Page 9: ...6 Figure 2 Two Wire Mode Figure 3 Four Wire Mode...

Page 10: ...antern batteries springs facing toward battery PC board Fig 4 4 Verify that the batteries are secure on the bottom of the housing and the backs are being held by the back plate You will notice the bat...

Page 11: ...e rechargeable batteries We recommend that rechargeable batteries be used when external power is supplied The ex ternal source should provide a voltage greater than 12 but less than 15 volts It will r...

Page 12: ...the warning beeps will come every 15 seconds At this point the MK2 DCI will audibly start warning you of lower power with a beeping sound every 30 seconds When the voltage falls to about 7 volts the r...

Page 13: ...volume Most of the time when there is too much volume the diver will hear distortion and ask for more volume 4 Before diving operations always check the battery power level and replace or recharge th...

Page 14: ...n power switch board is turned on Defective CPU chip Replace CPU or replace board No diver voice Loose connection at Check connector ribbon lead connector clean or reconnect Board connectors Clean pin...

Page 15: ...mp Trace fault around record op amp and replace faulty part Replace board Weak output to divers Power amplifier Replace power and tender defective amplifier chip Defective component Trace part and rep...

Page 16: ...he complete unit and or part must be returned to our factory transportation charges prepaid We reserve the right to decline responsibility where repairs have been made or attempted by other than an Oc...

Reviews: