Appendix A: Troubleshooting

Problem

Solution

The LED is not lit

Check that the power cable is connected properly.
Check that the Amigo eZync is turned on.

The LED is blinking

The Amigo eZync is running on battery back-up.
Check that the power cable is connected properly.

It is not possible to 
synchronise the 
Amigo eZync

Synchronisation takes place wirelessly with the aid of an Amigo 
T20/T21/WRP. If the Amigo eZync fails to confirm (with three 
blinks of the LED), try moving the transmitter closer or a little bit 
to one side. Then press the SYNC button again.
It is possible to synchronise the Amigo eZync during the first 60
seconds after it is turned on. To change the channel, turn the 
Amigo eZync off and on again, and synchronise it once more.

For assistance with troubleshooting, or for answers to other questions, please consult 
your hearing care professional. Alternatively, visit www.oticon.com, where you can find a 
troubleshooting guide for Amigo.

Summary of Contents for Amigo eZync

Page 1: ...INSTRUCTIONS FOR USE Amigo eZync ...

Page 2: ...annels 15 Synchronising the Amigo eZync 16 Synchronising other manufacturers receivers 17 Cleaning the Amigo eZync 18 Appendix A Troubleshooting 19 Appendix B Manufacturers warranty 20 Warning Yellow pages IMPORTANT NOTICE Please familiarise yourself with the entire contents of this booklet before using your Amigo eZync The booklet contains various statements safety instructions and important info...

Page 3: ... making life much easier for users in academic professional and social listening situations With Amigo eZync channel management in educational surroundings have become even more manageable Amigo eZync is easy to mount on a wall or place on a shelf based on the needs that are for the specific school or institution Typical package content Wall mount Fasteners and anchors Instructions for use Power s...

Page 4: ...y back up that will last for up to 48 hours It will automati cally switch to battery power when the mains power is disconnected and vice versa The back up battery may take several hours to charge when the Amigo eZync is powered for the first time The battery charges continuously whenever the Amigo eZync is plugged in NOTE The battery cannot be replaced by the user The Amigo eZync cannot be opened ...

Page 5: ...on is close to the door or in the corridor just outside the classroom Then you can be absolutely certain that all receivers will be continuously synchronised and on the right channel NOTE The Amigo eZync will automatically synchronise all Amigo ear level receivers within range and in all directions 360 Synchronisation can also take place through walls NOTE It the wall outlet is located too far awa...

Page 6: ...t anchors inside the drilled holes 3 Insert fasteners through the washer and wall mount 4 Gently tighten the until the wall mount is secure Avoiding bending the wall mount 5 If the Amigo eZync is to be used in a room where only younger kids are entering the Amigo eZync can be mounted lower than the recommended 1 5 meters NOTE When installing the wall mount note that the fasteners must not be over ...

Page 7: ... slide the unit to the left to lock it 2 in place To remove the Amigo eZync lift it a little and slide it to the right 3 Placing the Amigo eZync on a shelf If If you occasionally need to move the Amigo eZync use the stand that is supplied with the Amigo eZync Simply connect the power cord and place the Amigo eZync on the shelf NOTE When using the portable stand avoid placing the Amigo eZync anywhe...

Page 8: ...annel on the Amigo T20 T21 WRP transmitter press and hold either the S button or the T button for two seconds to select one of the prede fined lists of channels When the channel number begins to blink press S or T to change channel As soon as you find the desired channel press the SYNC button to confirm The transmitter will then be locked on to the new channel When the channel number is blinking y...

Page 9: ... press the SYNC button on the Amigo T20 T21 WRP If the synchronisation is successful the LED on the Amigo eZync will blink three times With the Amigo eZync you have the possibility to synchronise Amigo ear level receivers and Widex ear level receivers Visit www oticon com for a full compatibility guide NOTE The Amigo eZync will not syncronise receivers during the first 60 seconds after it has been...

Page 10: ...Zync Synchronisation takes place wirelessly with the aid of an Amigo T20 T21 WRP If the Amigo eZync fails to confirm with three blinks of the LED try moving the transmitter closer or a little bit to one side Then press the SYNC button again It is possible to synchronise the Amigo eZync during the first 60 seconds after it is turned on To change the channel turn the Amigo eZync off and on again and...

Page 11: ... of purchase Transportation must be paid by the customer If it is determined that repair is not feasible the entire unit may be replaced with an equivalent unit upon mutual agreement between the hearing care professional and customer What is not covered by this warranty This one year limited warranty does not cover Malfunctions resulting from abuse neglect or accident Peripheral accessories as ite...

Page 12: ... you might have under applicable national legislation governing the sale of consumer goods Your point of purchase may have issued a warranty that goes beyond the clauses of this limited warranty Please consult your point of purchase for further information The Amigo eZync contains a radio transmitter using short range inductive technology working at 3 714 MHz The magnetic field strength of the tra...

Page 13: ...the USB connector is connected to mains operated equip ment this equipment should be UL approved or comply with equivalent safety require ments The Amigo eZync contains a radio transmitter with ID U28EZYNC01 IC 1350B EZYNC01 The device complies with Part 15 of the FCC rules and RSS 210 of Industry Canada Operation is subject to the following two conditions This device may not cause harmful interfe...

Page 14: ...ause serious injury The Amigo eZync complies with the most stringent standards of International Electro magnetic Compatibility However the unit may cause interference with other medical devices such as defibrillators and pacemakers Please contact the manufacturer of your implantable device for information about the risk of disturbance Interference can also be caused by power line disturbances airp...

Page 15: ......

Reviews: