OT Systems FT110AB Series Installation And Operation Manual Download Page 2

FT110AB Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

 

Models covered in this manual 
 

Standalone Units 

 

Single-Mode Transmitters 

FT110AB-SSTSA 

FT110AB-SSTLSA 

 

Single-Mode Receivers 

FT110AB-SSRSA 

FT110AB-SSRLSA 

 

Multi-Mode Transmitter 

FT110AB-SMTSA 

 

Multi-Mode Receiver 

FT110AB-SMRSA 

 

Card Modules 

 

Single-Mode Transmitters 

FT110AB-SST 

FT110AB-SSTL 

 

Single-Mode Receivers 

FT110AB-SSR 

FT110AB-SSRL 

 

Multi-Mode Transmitter 

FT110AB-SMT 

 

Multi-Mode Receiver 

FT110AB-SMR

 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

Remark: 

If the optical connector is FC type, the suffix in the model number will be 

“-

F

XX”.

 Eg. 

FT110AB-

F

ST 

Summary of Contents for FT110AB Series

Page 1: ...ll Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT110AB Series 10 bit Digital Series 1 ch Video with 1 ch Duplex Audio Fiber Optic Converter OT Systems Ltd 2009 Rev 1 1 ...

Page 2: ...eivers FT110AB SSRSA FT110AB SSRLSA Multi Mode Transmitter FT110AB SMTSA Multi Mode Receiver FT110AB SMRSA Card Modules Single Mode Transmitters FT110AB SST FT110AB SSTL Single Mode Receivers FT110AB SSR FT110AB SSRL Multi Mode Transmitter FT110AB SMT Multi Mode Receiver FT110AB SMR Remark If the optical connector is FC type the suffix in the model number will be FXX Eg FT110AB FST ...

Page 3: ...able 5 3 INSTALLATION 6 3 1 General 6 3 2 Standalone unit installation 6 3 3 Card module installation 7 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 3 Ground connection 10 5 OPERATIONAL GUIDES 10 5 1 FT110AB Series Transmitter 10 5 2 FT110AB Series Receiver 11 6 SPECIFICATIONS 12 7 DRAWINGS 13 8 WARRANTY INFORMATION 13 9 CONTACT INFORMATION 13 ...

Page 4: ...o Class I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing operations which are other than those specified may result in hazardous radiation exposure Permanent eye damage or other bodily injuries may be resulted from such exposure even for only seconds Note 2 Thi...

Page 5: ...audio inputs and outputs are supported Optical Wavelength Division Multiplex WDM technique is also employed for simultaneous reverse audio signal transmission For single mode transmission we also offer specifically designed products for long haul transmissions up to 60km These models include the letter L in the suffix e g FT110AB SSTL for Tx FT110AB SSRL for Rx etc The FT110AB Series units are ava...

Page 6: ...er 1 Ch Audio Transceiver Standalone Unit FT110AB SMRSA Multi mode 1 Ch Video Receiver 1 Ch Audio Transceiver Standalone Unit Card Modules Single Mode FT110AB SST Single mode 1 Ch Video Transmitter 1 Ch Audio Transceiver Card Module Housed in FT C18 chassis 3 FT C18 chassis has to be ordered separately FT110AB SSTL Single mode Long haul 1 Ch Video Transmitter 1 Ch Audio Transceiver Card Module FT1...

Page 7: ...n be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture either on the wall or on a flat surface with four screws through the holes on the mounting frame to secure it in position b The provided power supply should also be mounted on the same fixture or in the proximity for connection of the supply cables to the unit provided that an AC power supply...

Page 8: ... front and back panels of the card modules are lit If not check the power supply cable connections between the chassis and the power supply socket For failures of individual card s POWER LEDs check the corresponding card modules whether they have been inserted properly e With all the signals available at the input and output ports check the status of LEDs located on the unit With correct status of...

Page 9: ...ation Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module to Card Module connection diagram ...

Page 10: ...O PORT 7 PIN User s Equipment 1 N A 1 N A 2 N A 2 N A Audio OUT 3 IN 3 IN Audio OUT Audio OUT 4 IN 4 IN Audio OUT Audio IN 5 OUT 5 OUT Audio IN Audio IN 6 OUT 6 OUT Audio IN 7 N A 7 N A Fig 4 4 1 Connector Pin Assignments for balanced audio signal at Audio port Un Balanced Audio signal connection diagram Transmit End Receive End User s Equipment AUDIO PORT 7 PIN AUDIO PORT 7 PIN User s Equipment 1...

Page 11: ...ndicator Color Description PWR Red Lit when power is supplied to the Transmitter OL Yellow Lit when optical signal from receiver to transmitter is active VIDEO IN VIN V1 Green Lit when video signals are fed into the VIDEO IN connectors AUDIO LEVEL IN Red a Each audio channel has a single column of Four LEDs assigned for displaying the input or output audio levels b The LEDs Input Output are lit in...

Page 12: ... Red a Each audio channel has a single column of Four LEDs assigned for displaying the input or output audio levels b The LEDs Input Output are lit in proportion to the signal strength c An increase decrease of signal level of about 3dB will light up turn off an individual LED All LEDs will go out at or less than 16dBm and all are lit when the level attains 6dBm or over OUT Green Signal Ports OPT ...

Page 13: ...utput Level 1 0 Vp p typical Differential Gain 1 typical Differential Phase 1 o typical SNR 65dB AUDIO Channel Connector 1 7 pin Screw Terminal Direction Bi directional Duplex Input Level Impedance 0dBm normal 10K ohms Balanced or Unbalanced Audio bandwidth 20Hz 20KHz Output Level 4dBm 1KHz SNR 66dB POWER Power consumption 12VDC 4 8W Power Supply Standalone Unit FT PA12V DC Adaptor Card module Pow...

Page 14: ...nty offered by the company in normal circumstances Please refer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 1023 10 F Landmark North 39 Lung Sum Avenue Sheung Shui N T Hong Kong Tel 852 2672 5153 Fax 852 2679 0756 sales ot systems com OT Systems Ltd US...