background image

d:\windoc\icp\project\5362_crio-dp_master\anwenderdoku\installation\version_1.6\crio_pb_e.doc 

Revision History 

 

Version 

Date 

Description 

Resp. 

 

 

 

 

 

 

 

 

V1.6 

03.03.2010  Minor Fixes 

SF 

V1.5 

16.02.2010  National Instruments specific changes 

SF, JK 

V1.4 

23.09.2009  Technical data table updated 

SF 

V1.3 

07.05.2009  Technical data table updated 

BS 

V1.2 

28.04.2009  Technical data table updated 

SF 

V1.1 

20.08.2008  Technical data table updated 

JK 

V1.0 

21.02.2008  Initial Version 

 

 

 

 

COMSOFT

 GmbH

 

Wachhausstrasse 5a 
76227 Karlsruhe 
Phone  +49 721 9497 - 0 
Fax 

+49 721 9497 - 129 

 
Copyright 

 2010 by 

COMSOFT

 GmbH 

 
 

Business Confidential/

COMSOFT

 Proprietary 

 

This document includes data that shall not be duplicated, used, or disclosed - in whole or in part - for any purpose other than 
to evaluate this document. If, however, a contract with a customer is in force, the customer shall have the right to duplicate, 
use, or disclose the data to the extent provided in this contract. This restriction does not limit the customer’s right to use the 
data in this document if it can also be obtained from another source without restriction. The data subject to this restriction are 
confidential in all pages of this document. 

 

Summary of Contents for BLSTMG-WOO

Page 1: ...CompactRIO PROFIBUS DP Installation Instruction V1 6 03 03 2010 COMSOFT CompactRIO PROFIBUS DP Installation Instruction V1 6 03 03 2010...

Page 2: ...se 5a 76227 Karlsruhe Phone 49 721 9497 0 Fax 49 721 9497 129 Copyright 2010 by COMSOFT GmbH Business Confidential COMSOFT Proprietary This document includes data that shall not be duplicated used or...

Page 3: ...03 2010 i Business Confidential COMSOFT Proprietary Contents 1 Installation of the Module 1 2 LEDs and Connectors 2 2 1 Position of LEDs and Connectors 2 2 2 LED s 3 2 3 Power connector 4 2 4 9 pin SU...

Page 4: ...s Confidential COMSOFT Proprietary List of Figures Figure 1 cRIO PB module 1 Figure 2 LEDs and connectors 2 Figure 3 Profibus Terminator cable type B is no longer used 4 List of Tables Table 1 Meaning...

Page 5: ...IP switch adjustments are necessary To mount the module in the CompactRIO or Single Board RIO proceed as follows Switch off the CompactRIO or Single Board RIO Plug the cRIO PB module into slot 1 until...

Page 6: ...T Business Confidential COMSOFT Proprietary 2 LEDs and Connectors 2 1 Position of LEDs and Connectors Figure 2 LEDs and connectors SPI Activity LED PWR Power indication LED RUN PROFIBUS Activity LED B...

Page 7: ...ve not active ON DP Slave initialized Flash fast DP Slave AutoSlaveMode waits for a DP Master to communicate Flash slow DP Slave AutoSlaveMode baud rate detection active BF Red Operation as DP Master...

Page 8: ...ements 2 4 9 pin SUB D connector Pin Number Signal Function Direction 1 shielding 3 RxD TxD P Data Input Output 5 0V potential free 80 mA Feeding of bus terminator Input 6 5V potential free 80 mA Feed...

Page 9: ...face 1 Port Sub D 9 pins Interface Physics RS485 isolated Profibus Data Rates 9600 Bit s 12000 Kbit s Data Size of Process Image max 8 KByte PROFIBUS Isolation Voltage 500 VDC Power Requirements 2 5 W...

Page 10: ...tial COMSOFT Proprietary 4 CE Conformity Declaration We herewith declare that the CompactRIO Module cRIO PB corresponds to the requirements stated in the EU standards 2004 108 EG The device correspond...

Reviews: