55
F A U L T D E T E C T I O N
1. Make sure that there is power to the fan.
2. Cut the power and verify that the impeller is not
blocked.
3. Check the thermal contact (for AC). If it is discon-
nected the cause of overheating must be taken care
of, not to be repeated. To restore the manual ther-
mal contact, cut the power for a couple of
minutes. Larger motors than 1,6 A may have manu-
al resetting on the motor. If it has automatic thermal
contact the resetting will be done automatically
when the motor has cooled.
4. Make sure that the capacitor is connected according
to the wiring diagram (for AC).
5. If the fan still does not work, the first thing to do is
to change the capacitor (for AC).
6. If nothing of this works, contact your fan supplier.
7. If the fan is returned to the supplier, it must be
cleaned, the motor cable undamaged and a detailed
nonconformity report enclosed.
W A R R A N T Y
The warranty is only valid under condition that the fan
is used according to this “Directions for use” and a regu-
lar maintenance has been made and record. The war-
rantor is responsible only for the operation if approved
accessories are used. The warranty does not cover pro-
duct failures caused by accessories/equipment from
other manufacturers.