Channel Port (Left and Right)

The Channel Ports transmit and receive signals on a specific CWDM wavelength. 

The Channel Ports are multiplexed on and demultiplexed from the Common Ports.  

As shown in Figure 3 and 4, a 1-Channel CWDM/AD supports a single channel in 

both directions and a 2-Channel CWDM/AD supports two channels in both directions.  

Each Channel Port has a Left and Right port.  Data transmitted and received by 

Channel Port Left is aggregated on Common Port Left and data transmitted and 

received by Channel Port Right is aggregated on Common Port Right.  

CWDM / AD

2 - 4

CWDM/X

1

2

3

4

CWDM/X

1

2

3

4

1

(Left)

1

(Right)

COM-L

COM-R

Figure 3: 1-Channel Add/Drop MUX/DEMUX

COM-L

COM-R

CWDM / AD

1

(Left)

1

(Right)

3 - 4

CWDM/X

1

2

3

4

CWDM/X

1

2

3

4

2

(Left)

2

(Right)

Figure 4: 2-Channel Add/Drop MUX/DEMUX

NOTE:  For more information on the 

iConverter

 CWDM/X modules, visit Omnitron’s 

website at: http://www.omnitron-systems.com 

Common Port (Left and Right)

The Common Ports transmit and receive the aggregated wavelengths connected to 

the Channel Ports.  As shown in Figures 3 and 4, there are Left and Right  Common 

Ports on the CWDM/AD module. Common Port Left (COM-L) and Common Port 

Right (COM-R) are internally connected to pass through all wavelengths not dropped 

or added by the specific CWDM/AD model. Only the specific wavelength of the 

model selected will be dropped to the appropriate Channel Port.  Common Port 

Left drops and adds wavelength traffic from Channel Port Left and Common Port 

Right drops and adds wavelength traffic from Channel Port Right. 

Page 2

Installation

1.  Carefully  slide  the  module  into  an  open  slot  in  an 

iConverter

  chassis. Align 

the  module  with  the  installation  guides  and  ensure  that  the  module  is  firmly 

seated against the backplane. Secure the module by fastening the front panel 

thumbscrew (push in and turn clockwise to tighten) to the chassis front. The 

CWDM/AD  module  requires  no  external  power,  however,  if  management  is 

required, the module must be installed in an 

iConverter 

powered chassis with 

a Network Management Module (NMM2 Model 8000N-0) or a media converter 

with integrated management (such as the 

iConverter

 10/100M2)*.

2.  Connect a single-mode, dual fiber duplex LC cable between the Channel Port of 

the CWDM/AD module and the attached device.  It is important to ensure that the 

wavelength of the CWDM/AD matches the wavelength of the attached device.  

When  connecting  the  Channel  Port,  make  sure  the  Left/Right  designation  is 

followed. This will ensure the data from the Channel Port is aggregated onto the 

corresponding Common Port. Ensure that the transmit (Tx) is attached to the 

receive side of the device at the other end, and the receive (Rx) is attached to 

the transmit side.

3.  Connect  a  single-mode,  dual  fiber  duplex  LC  cable  between  the  Common 

Ports on the CWDM/AD module(s) (this connection may be made through fiber 

patch panels since the modules may not be co-located) or CWDM/X devices.  

When connecting between the Common Ports on the CWDM/AD modules, it 

is recommended to connect the Common Port Right (COM-R) to the Common 

Port Left (COM-L) on the other CWDM/AD module. Ensure that the transmit 

(Tx)  is  attached  to  the  receive  side  of  the  device  at  the  other  end,  and  the 

receive (Rx) is attached to the transmit side.

NOTE:  For proper installation, a network diagram indicating port designations is 

recommended.
NOTE:  The 

iConverter

 CWDM/AD modules can not be installed in slots 4, 8, 12 and 

16 of a 19-Module Chassis or in the top slot of a 2-Module Chassis or in a 1-Module 

Redundant Power Chassis.
*For complete management functionality, use M2 series (NMM2, GX/TM2, 2GXM2. 

10/100M2, 2FXM2) or higher.

Design Considerations

iConverter 

CWDM/AD modules are passive devices that require no external power.   

Attenuation (signal loss) of less than 1.9dB will be realized through each port on the 

module (see the CWDM/AD Data Sheet for exact loss specification for each model).  

Detailed calculations should be performed for each fiber optic link in the network to 

ensure the proper optical devices are specified with sufficient transmitter power.  
When calculating optical loss, ensure that the total loss, plus a safety factor (typically 

3dB), does not exceed the optical power budget.  The optical power budget is the 

difference between the transmitter optical output power and the receiver’s optical 

sensitivity. 

Page 3