www.traxontechnologies.com | www.osram.us/traxon
©2021 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS
PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Installation Guide
V1.1 03/21
P. 18 of 24
5. Install the termination resistor (included in the termination kit) between the Data - and Data + conductors on
the last unit in the control. See Figure 23 for specific wire connections.
NOTICE
Termination is required for proper operation and shall be applied at the last unit of
the daisy chain only. Failure to apply termination correctly will void the warranty.
FIG.17: DMX Termination Detail
DMX +
DMX -
DMX +
DMX -
Data pair to luminaire
To ProPoint luminaire
Data pair from luminaire
WAGO 221-412 Lever Nut
(Typical of 6)
120 Ohm Terminator
Orange
DMX- IN
Red
DMX+ IN
Grey
DMX- OUT
Purple
DMX+ OUT
NOTE
• Maintain data pair wire twist at all connection points.
• To prevent short circuits, do not strip more conductor insulation than required for
connection.
• The use of wire nuts is not acceptable and will void the warranty.
• Data termination shall be made in weatherproof enclosure by others. Use suitable
cable glands and apply RTV silicone at all entry points.
NOTICE
Data shall enter each luminaire using the DMX In wire pair (Orange and Red
conductors). A 120 Ohm termination resistor shall be installed on the DMX Out wire
pair (between Grey and Purple conductors). Failure to terminate at the last luminaire
will void the warranty and may result in control issues.
FIG.18: DMX Termination Detail