![Osram OT EASY 32 CC Fitting Instructions Download Page 2](http://html1.mh-extra.com/html/osram/ot-easy-32-cc/ot-easy-32-cc_fitting-instructions_1656447002.webp)
Page 2 of 3
Installation (cont.)
8,5-9,5 mm
16 mm
8,5-9,5 mm
16 mm
8,5-9,5 mm
M
N
O
P
C
H
4
C
H
3
C
H
2
C
H
1
S
EC
35
0
m
A
/C
h.
SE
LV
-
eq
uiv
.
E
A
S
Y
sig
na
l
12
0-2
40
V
50
/6
0
H
z
P
R
I
DO NOT
USE
SE
LV
-
eq
uiv
.
L
Connecting the control unit
Notes
• Max. line length to LED modules: 10 m
• Line cross-sections and cable diameters/sizes:
Connection
Line cross-
section
Cable diameter/
size
Power supply
0.5 – 1.5 mm²
7 – 11 mm
External
pushbutton
0.2 – 0.5 mm²
3.2 x 5.2 mm
EASY signal
–
2.2 x 4.7 mm
LED modules
0.5 – 1.5 mm²
7 – 11 mm
• Only use LED series circuits at every LED output.
• Only use LED modules/fixtures with separated anodes and
cathodes.
• The maximum number of LEDs that can be connected in se-
ries to each output channel is limited by the forward voltage
V
f
of the individual LEDs, the control unit output voltage and
the cable voltage drop (e.g. V
f
= 3,5 V à max. 6 LEDs). De-
tails on the limitations can be found in the OPTOTRONIC
®
technical instructions.
• A different number of LEDs per channel (not more than the
max. number each) is allowed. Automatic load detection is
performed at power-on.
• To be able to use the colour/colour temperature algorithm of
EASY Color Drive and EASY Hybrid Remote, channels and
LED types are assigned as follows:
Channel
RGB+W
WW / CW
(Tunable White)
CH1
Red
Warm white
CH2
Green
Warm white
CH3
Blue
Cold white
CH4
White/amber
Cold white
• In combination with other types of EASY control units,
4-channel tunable white configurations require to set one
OT EASY 32 CC as master.
• Master-slave connection: Max. 1 master and 15 slaves con-
nectable, see “Connecting the inputs”.
Connecting the inputs
Connect the 4p4c modular connector (N) of the EASY signal
line.
Strip the power cable (M), remove the insulation from the
phase and neutral conductors and connect to the terminals.
Connect the line of the external pushbutton to the terminals,
if applicable, or insert the short circuit bridge (O) for slave
mode. Lead external push-button cable and EASY signal ca-
ble together (overlapped) through one opening (L) to ensure
a correct cable clamping function.
Use cable clamps.
Insulate the cable PE conductor, if necessary.
Connecting the outputs
Strip the 4-wire lines (P), remove the insulation and connect
to the terminals. Do not connect the terminals labeled “DO
NOT USE”.
Use cable clamps.