Osram EASY Hybrid Remote Fitting Instructions Download Page 2

Page 2 of 2

 

10-24 V DC

-

+

+

-

1

2

3

4

Easy Signal

DALI EASY III

L

N

GND (-)

CH4+ (W)

CH3+ (B)

CH2+ (G)

CH1+ (R)

Easy signal

24 V (+)

CH1 (R-)

CH2 (G-)

CH3 (B-)

CH4 (W-)

GND (-)

OT EASY 60 II

L

N

Y-Connector 

Screw

1

2

3

4

N

R

Q

Connection diagram

N   Mounting plate on the back of the wall bracket

Q  DC supply (optional)
R  EASY Bus connection (optional)

Attachment on flush-mounted box and 

optional electrical connection



  Shorten the connection wires so that they protrude approx. 

5-6 cm from the flush-mounted box.

‚

  Strip the required connection wires by approx. 5 mm. Insu

-

late any connection wires not needed.

ƒ

  Pass the required connection wires through the centre open

-

ing of the mounting plate (N).

„ 

 

Align the mounting plate (N) and attach it to the flush-

mounted box. Ensure that it is seated securely, sliding the 

mounting plate up or down or to the left or right by a few 

millimetres if necessary.

…

 Optional: Connect and test the DC supply: 

CAUTION!

Destruction of components connected to EASY bus!

•  Do not connect the DC supply to the EASY bus.

Connect the supplied 2-pin plug-in connector to the DC 

power supply and plug it into the corresponding socket (Q) 

on the back of the wall bracket. 
Test: Take the batteries out of the hand-held transmitter and 

switch on the DC supply. Insert the hand-held transmitter 

into the wall bracket from above and press down. 

à

 The LCD lighting must light up. Switch off the DC supply.

†

  Optional: Connect the EASY bus after the DC supply test 

was successful.  

Connect the supplied 4-pin plug-in connector to the EASY 

bus wires and plug it into the corresponding socket (R) on 

the back of the wall bracket.

‡

  Bend away the connecting wires in an S-shape and place 

the wall bracket onto the mounting frame from above. En

-

sure that the wires do not press against the wall bracket and 

are not pinched.

ˆ 

 

Attach the wall bracket using the supplied mounting screws 

(O).

‰ 

 

Hand-held transmitter as a permanent wall operating unit 

(optional): Fix the hand-held transmitter from below with the 

supplied fixing screws (P).

Appendix

Accessories

Note:  

The accessories are not included.

Designation 

Description 

Product number

Y-CONNECTOR screw 

Y-connector with screw terminals 

for EASY signal connection with 

4-pin cable

4008321916686

OT 6/200-240/24 

 

24 V power supply unit for flush-

mounted box installation,

 

power supply range 220-240 V 

4008321113269

Disposal

Do not dispose of the device and batteries with 

household waste. 

Electronic devices must be disposed of at local 

recycling centres for waste electronic equipment in 

accordance with EU Directive 2002/96/EC on waste 

electrical and electronic equipment.

Installation (cont.)

 

Conformity with the relevant EU directives is 

confirmed by the CE symbol. 