background image

31

Dismounting

The device enters the bootloader mode and the firmware loader window 

is displayed:

4. 

Browse for the new firmware file and click “upload” to start the 

updating process. Wait until the process has finished to get back to 
normal operation. Acknowledge the firmware version and the Dashboard 

page appears. 

The firmware update is completed.

To abort the firmware update, click “abort and restart”. Wait for the device 

to reboot. 

9  Dismounting

Disconnect all attached cables. Dismount the e:cue SYMPL bridge Node 
from the rail by pulling the black DIN rail handle and unhitching the SYMPL 
Node. The dismounting is completed.

!

Before dismounting, appropriate measures must be taken to 
protect the respective components against damage caused 
by electrostatic discharge (ESD protection).

Summary of Contents for AM356970031

Page 1: ...Our Brand www osram com ecue Light is OSRAM AM356970031 e cue SYMPL bridge Node Information for Use Bedienungsanleitung...

Page 2: ...gsanleitung Originalversion Edition Ausgabe 23 07 20 EN_DE_SYMPL_bridge_Setup_v1p2 Published by Herausgegeben von OSRAM GmbH Karl Schurz Strasse 38 33100 Paderborn Germany 2020 OSRAM GmbH BU Digital A...

Page 3: ...ts as well as exploitation and or communication of the contents is not permitted Lesen Sie die Installationsanleitung und das Heft Sicherheitshinweise sorgf ltig durch Alle nderungen vorbehalten Recht...

Page 4: ...13 3 General remarks 14 3 1 Transport 14 3 2 Unpacking 14 3 3 Warranty regulations 14 3 4 Maintenance and Repair 14 3 5 Disposal 15 3 6 Support 15 4 Installation 15 4 1 Installation conditions 16 4 2...

Page 5: ...4 12 Sicherheitshinweise 35 12 1 Symbole 35 12 2 Sicherheitshinweise 35 13 Ger tebeschreibung 36 13 1 Lieferumfang 37 13 2 Anschl sse und Schnittstellen 38 13 3 Benutzeroberfl che LEDs 39 13 4 Identif...

Page 6: ...ber SYMPHOLIGHT 47 16 3 Netzwerkeinstellung ber die Webschnittstelle 48 17 Ausgabe Konfiguration 50 17 1 Ausgangs Konfiguration 51 17 2 Datenzuordnung Quellen Konfiguration 53 17 3 Quellenwechsel 55 1...

Page 7: ...07 English...

Page 8: ...vices i The information symbol gives general hints and informs about handling and procedures for use of the device 1 2 General security instructions Connect cables and data only when the device is pow...

Page 9: ...et and e net Switch between two input sources on the fly The SYMPL bridge Node makes it possible to run up to 4096 DMX channels 1360 RGB pixels 170 pxl universe via DMX universes and up to 16 384 DMX...

Page 10: ...er AM356970031 1 SYMPL bridge Node 2 Safety instructions 3 Installation guide i To operate SYMPL Nodes a SYMPHOLIGHT version 2 0 or higher is mandatory Earlier versions do not support the SYMPL Nodes...

Page 11: ...X output 1 8 GND DMX DMX left to right 2 DMX e pix status LEDs 3 Test Error LED 4 Ethernet LED LAN activity 5 Status LED Device status 6 Identify button 7 Test button 8 Protective Earth 9 Power supply...

Page 12: ...ernet Off no link available On link established Blinking Ethernet traffic Test Error Off no error detected Short short long sequence Test mode active On If constantly lights in red an error occurred T...

Page 13: ...Test Error LEDs light up at first Bootloader mode is signaled by a fast blinking Status LED Release the button now The device stays in bootloader mode to download a new firmware To exit the bootloade...

Page 14: ...ontent page 10 If there is apparent damage to the device or parts are missing from the delivery scope please contact the OSRAM support service 3 3 Warranty regulations Depending on the product guarant...

Page 15: ...pair please contact OSRAM GmbH Customer Service Karl Schurz Str 38 33100 Paderborn Deutschland 49 5251 54648 0 support ecue com 4 Installation The installation of the SYMPL bridge Node consists of mou...

Page 16: ...l from top 2 Apply gentle pressure to the top front to snap it in place The device has been mounted successfully You can also mount the device on any flat surface Use a 3 to 3 5mm screw for the hanger...

Page 17: ...The e cue SYMPL bridge Node can be powered by an external power supply or via Power over Ethernet PoE For PoE simply connect an Ethernet connection from a power sourcing device External power supply...

Page 18: ...finished booting and is in operation when the LED Status is flashing 4 6 Protective Earth Grounding of the SYMPL bridge Node Use Protective Earth where applicable Ground the DMX connection cable and...

Page 19: ...Default network properties The SYMPL bridge Node has as factory setting the default IP address 192 168 123 1 Subnet mask 255 255 255 0 DHCP is disabled by default Login credentials for the web interf...

Page 20: ...needs 4 Click Apply to submit the changes The network configuration of the device is completed 5 3 Network configuration with the web interface 1 Open a common web browser on a connected PC Enter the...

Page 21: ...ou can also change the password for entry to the web interfaces of the device here Entering an empty value disables the password protection 5 Click Submit to apply the settings The network configurati...

Page 22: ...login password to the SYMPL bridge Node s configuration page and its device name at Settings page Do not forget the new password i The SYMPL bridge Node should be only accessed from one browser tab at...

Page 23: ...s configuration page by selecting Output Configuration on the left side of the web interface of the SYMPL bridge Node 2 Select the type of protocol the connected fixtures support You can address up to...

Page 24: ...3 After configuring all ports click the submit button to save the configuration 6 2 Data mapping Sources configuration The second step of the output configuration is to configure the data input The S...

Page 25: ...source 2 At the top select a protocol type Art Net e net sACN from the drop down menu and click the configure button In the protocol configuration configure the source protocol parameters e g the IP a...

Page 26: ...be taken to do a fade out fade in between the two input sources 1 Open the source switch configuration page by selecting Source Switch Settings on the left side of the web interface of the SYMPL brid...

Page 27: ...signed for DMX luminaires There are two kinds using the Test button and using the web interface of the SYMPL bridge Node Please note that the Test mode overwrites all other DMX output like running sho...

Page 28: ...rom the beginning To exit the Test mode at any time keep the Test button pressed for 5 seconds The device proceeds to normal operation The DMX LEDs no longer flicker and the Test Error LED is off For...

Page 29: ...PL bridge Node only Block Size Block size in which to step through the frame length in channel count Offset Start address of the first test loop first channel 1 Value Luminance of the test output 0 25...

Page 30: ...e usual update options in the Device Tree of the Setup tab in SYMPHOLIGHT select Update firmware in the context menu of the SYMPL bridge Node or click the Update button in the head toolbar Updating wi...

Page 31: ...Dashboard page appears The firmware update is completed To abort the firmware update click abort and restart Wait for the device to reboot 9 Dismounting Disconnect all attached cables Dismount the e...

Page 32: ...perature 40 70 C 4 158 F Operating storage humidity 0 80 RH non condensing Protection class IP20 Electrical safety class SELV Housing Self extinguishing blend PC ABS UL E140692 Mounting on 35 mm DIN r...

Page 33: ...40 120 C 0 2 C 40 248 F 0 36 F Humidity 0 100 2 User interfaces LEDs for Test Error Ethernet activity device status DMX status Identify button Test button 70 C 158 F for max 1 hour day continuous oper...

Page 34: ...34 Deutsch...

Page 35: ...ssenen Ger ten i Das Informationssymbol gibt generelle Hinweise und informiert ber Handhabung oder Verfahren zur Verwendung des Ger tes Verbinden Sie Anschl sse nur wenn das Ger t ausgeschaltet ist Er...

Page 36: ...und e net Wechseln Sie im Betrieb zwischen zwei Eingabequellen Der SYMPL bridge Node erm glicht die Kontrolle von bis zu 4096 DMX Kan len 1360 RGB Pixel 170 Pxl Univ ber DMX Universen und bis zu 16 38...

Page 37: ...31 umfasst 1 SYMPL bridge Node 2 Heft Sicherheitshinweise 3 Installationsanleitung i Mindestanforderung f r die SYMPL Nodes ist eine SYMPHOLIGHT Version ab 2 0 Fr here Versionen oder die e cue Lightin...

Page 38: ...1 8 GND DMX DMX links nach rechts 2 DMX e pix Status LEDs 3 LED Test Error 4 LED Ethernet LAN Aktivit t 5 LED Status Ger testatus 6 Identify Taster 7 Test Taster 8 Erdung 9 Spannungsversorgung Vcc Vc...

Page 39: ...Ein Ethernet Verbindung verf gbar Blinken Datenverkehr ber Ethernet Test Error Aus kein Fehler erkannt Kurz kurz lang Sequenz Test Modus aktiv An Falls konstant rot ist ein Fehler aufgetreten Dies kan...

Page 40: ...gen auf Werkseinstellungen zur ckgesetzt Bitte beachten Sie dass der Ger tename nicht zur ckgesetzt wird Halten Sie den Identify Taster w hrend des Hochfahrens gedr ckt Die Status und die Test Error L...

Page 41: ...ort Transportieren Sie das Ger t nur in seiner Originalverpackung um Sch den zu vermeiden 14 2 Entpacken Entpacken Sie das Ger t nur am Installationsort Um Sch den bei Wechsel von K lte zu W rme durch...

Page 42: ...r tes ist Aufgabe des jeweiligen Benutzers und erfolgt zu seinen Lasten Im brigen richtet sich die R cknahmeverpflichtung f r Verpackung und Ger t nach den einschl gigen gesetzlichen Bestimmung Vor Be...

Page 43: ...ng eine Ethernet Verbindung und DMX e pix Ger te an Die Reihenfolge der Kabelanbindung ist beliebig Schalten Sie die Stromversorgung erst an wenn alle Kabel angeschlossen sind Liegt Spannung an beginn...

Page 44: ...ite F r optimale mechanische Stabilit t wird die Montage auf einer Hutschiene empfohlen 15 3 Ethernet Verbindung Die Anschlussbelegung des Ethernet Ports entspricht den Standards f r RJ45 Alle blichen...

Page 45: ...en Netzteil oder ber Power over Ethernet PoE PoE Schlie en Sie bei der Verwendung von PoE nur einen Ethernet Anschluss von einem PoE Versorger Midspan Endspan Device an Externes Netzteil Verbinden Sei...

Page 46: ...bridge Node ber Schutzerdung in den vorgegebenen F llen Erden Sie die DMX und Ethernet Anschl sse Erden Sie jedes Kabel separat i Der SYMPL bridge Node ist nicht f r den Betrieb ber ein Versorgungsnet...

Page 47: ...vom Netzwerk Der e cue SYMPL bridge Node hat als Werkseinstellung die Standard IP Adresse 192 168 123 1 Subnetz Maske 255 255 255 0 DHCP ist standardm ig deaktiviert Zugangsdaten f r die SYMPL bridge...

Page 48: ...ein 4 Klicken Sie auf Apply um die Einstellungen zu bernehmen Die Netzwerk Konfiguration vom SYMPL Node ist abgeschlossen 16 3 Netzwerkeinstellung ber die Webschnittstelle 1 ffnen Sie auf einem angesc...

Page 49: ...on Die Webschnittstelle des Ger ts wird angezeigt 2 W hlen Sie auf der linken Seite den Men eintrag Settings aus und geben Sie das voreingestellte Passwort ecue ein 3 Klicken Sie Apply und die Setting...

Page 50: ...ieren Sie sich alle vergebenen und gegebenenfalls reservierten IP Adressen mit zugeh rigem Ger t Bewahren Sie diese Information f r zuk nftige Netzwerkkonfigurationen auf i Unter Device Settings auf d...

Page 51: ...elle zu gelangen ffnen Sie einen gew hnlichen Webbrowser auf einem angeschlossenem PC Geben Sie die IP Adresse von dem Ger t in die Adressleiste ein z B http 192 168 123 1 17 1 Ausgangs Konfiguration...

Page 52: ...n Ausgang adressieren Bilden Sie verwendeten Adressen der angeschlossenen Leuchten ab um ein nahtloses e pix Universum zu erhalten geben Sie f r jeden Ausgang die Summe der von den Leuchten verwendete...

Page 53: ...ritt der Ausgabe Konfiguration bildet die Konfiguration der Dateneing nge Der SYMPL bridge Node bietet zwei Datenquellen F r jede Quelle sind zuerst das Protokoll und seine Parameter festzulegen Proto...

Page 54: ...ede Quelle 2 W hlen Sie oben auf der Seite eine Protokollart Art Net e net sACN vom Drop down Men aus und klicken Sie den configure Knopf In der Protokoll Konfiguration stellen Sie die Parameter f r d...

Page 55: ...chsel Der dritte Schritt der Ausgabe Konfiguration ist die Konfiguration der dritten Quelle die den Wechsel zwischen Quelle 1 und Quelle 2 bestimmt Die Werteauspr gung dieser Quelle steht f r das Einb...

Page 56: ...Bitte beachten Sie dass bei einer ordentlich definierten Wechselquelle der manuelle Wechselbefehl von eingehenden Quellendaten berschrieben wird Um das berschreiben zu verhindern setzen Sie den Chann...

Page 57: ...aster erneut jeweils kurz um zwischen den 8 DMX Ausg ngen und den vier Testbildern zu wechseln Im Anschluss an den Test des DMX Ausgangs Nr 8 werden alle DMX Ausg nge gleichzeitig getestet Ein weitere...

Page 58: ...sprechende Schaltfl che Legen Sie die Einstellungen fest Eigenschaft Beschreibung Output DMX Ausg nge auf denen der Test l uft Channel Count Absolute Frame L nge Editierbar nur in der e pix Version un...

Page 59: ...9 Firmware Update Ist eine neue Firmware verf gbar bieten sich zwei M glichkeiten das Ger t zu aktualisieren Aktualisierung mit SYMPHOLIGHT Verwenden Sie die blichen Update Optionen im Device Tree vom...

Page 60: ...en Warten Sie bis der Vorgang beendet ist und der Normalbetrieb wieder aufgenommen wurde Best tigen Sie die Firmware Version und das Dashboard des Ger ts wird angezeigt Das Firmware Update ist abgesch...

Page 61: ...utschienen Entriegelung ziehen und das Ger t von der Hutschiene l sen Die Demontage ist abgeschlossen Vor der Demontage m ssen geeignete Vorsichtsma nahmen ergriffen werden um die entsprechenden Kompo...

Page 62: ...mperatur 40 70 C Betriebs Lagerfeuchte 0 80 RH nicht kondensierend Schutzklasse IP20 Elektrische Sicherheit SELV Geh use Selbstl schendes PC ABS nach UL E140692 Montage Auf 35 mm DIN Hutschiene EN 607...

Page 63: ...pannungsschutz Sensoren intern Temperatur 40 120 C 0 2 C Feuchtigkeit 0 100 2 Bedienerschnittstellen LEDs f r Test Fehler Ethernet Aktivit t Ger testatus und DMX Status Identify Taster Test Taster 70...

Page 64: ...64 Dimensions Abmessungen All dimensions in mm Alle Abmessungen in mm 62 92 143...

Page 65: ...es com OSRAM GmbH Sales Operations Karl Schurz Str 38 33100 Paderborn Deutschland 49 5251 54648 0 support ecue com www ecue com Head office Zentrale Marcel Breuer Strasse 6 80807 Munich Germany Phone...

Reviews: