5.  ELECTRICAL CONNECTION

Connection to the electricity mains must be carried out by a qualified electrical installer.
This luminaire is designed for operating at a nominal voltage of 100 V - 240 V. It is fitted with a power supply cable (18 AWG yellow/green, brown and
blue cables). Check that the mains frequency and voltage correspond to those for which the luminaire is designed.
For your own safety, make sure the earth wire (yellow-green) is 

ALWAYS

connected to earth.

The power requirement is as following:

1. Turn the main power switch off first 
2. Connect the conductors in the power cable to the distribution circuit as follows:

Connect the brown wire to live (one phase).
Connect the blue wire to neutral.
Connect the yellow/green wire to ground (earth).

3. Check that all installation work is completed and carry out appropriate tests and safety checks before applying power.

Important Remark 

Power supply cables and other connections are essential for your equipment and contribute greatly to a safe and trouble-free operation.
1. Always hold the plug when disconnecting a cable, never pull the cable.
2. Never use cables or connections in bad condition, check them before installation and periodically thereafter. 
3. Never tie power supply and data cables together.

Yellow/Green

5

Power cord colors  

- Fig. 5

6. DMX CONNECTION 

Connect a female XLR5 cable into the luminaire’s DMX In input connector.
To send DMX 512 to another luminaire, connect a male XLR5 cable into the luminaire’s DMX Out connector.
To control the units with a DMX 512 controller, you will need to set DMX address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button up to when the DMX Address is showing on the display. Pressing the ENTER button and the display will blink. Use the DOWN/UP
button to change the DMX512 address. Once the address has been selected, press the ENTER button to setup, to go back to the functions without any
change press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the menu mode. 
Please refer to the following diagram to address your DMX512 channel for the first 4 units

Channel mode

Unit 1

Address

Unit 2

Address

Unit 3

Address

Unit 4

Address

1 channels

1

2

3

4

2 channels

1

3

5

7

Summary of Contents for ADB STAGELIGHT AL2319C41200

Page 1: ...0 Warm White Black finishing AL2519C41201 LEXPERT EMPHASY DMX 19 Daylight Black finishing AL2526C41201 LEXPERT EMPHASY DMX 26 Daylight Black finishing AL2536C41201 LEXPERT EMPHASY DMX 36 Daylight Blac...

Page 2: ...TION 2 FEATURE 3 SPECIFICATIONS 4 INSTALLATION 4 1 Lamp Hook Installation 4 2 How using a gobo and the gobo holder 4 3 Metal filter frame Installation 5 ELECTRICAL CONNECTION 6 DMX CONNECTION 7 MAIN F...

Page 3: ...rachige Version des Handbuchs mit Sicherheitshinweisen f r dieses ADB Produkt unter folgendem Link herunterladen www adbstagelight com Rif FIS00V Safety Information LEXPERT Emphasy C mo obtener tu INF...

Page 4: ...ing focus lens The product takes advantage of the heat pipe heat conduction and housing feature to dissipate heat without any fan Light Source 1 x 36W Cool Warm white LED Color temperature 3200k 150K...

Page 5: ...03 801 2 3 1 3 Put the gobo by hand into the gobo holder insert the gobo holder into the slot of the unit Fix the clamp using the screw to the lamp hanger of the fixture as shown above and fasten the...

Page 6: ...art of the filter frame holder by hand as displays the arrow and move away the Lock as the arrow then insert the metal filter frame into the inside slot from topside and close the frame holder Metal F...

Page 7: ...peration 1 Always hold the plug when disconnecting a cable never pull the cable 2 Never use cables or connections in bad condition check them before installation and periodically thereafter 3 Never ti...

Page 8: ...minaire s Dimming curve Menu 4 Control the luminaire locally Menu 7 Find out for how many hours the luminaire has been used Menu 9 Find out the firmware version number Menu 10 Accessing menus Press th...

Page 9: ...on Use the DOWN and UP buttons to select the blackout mode or last state Once the mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU b...

Page 10: ...ess the ENTER button and the display will blink Use the DOWN and UP buttons to select dimmer Once the mode has been selected press the ENTER button to setup the value from 0 to 255 to go back to the f...

Page 11: ...re the mains voltage on the main connector 2 The display is On Enter in Manual mode and set the value at 255 If the fixture doesn t light up contact your local dealer If the fixture lights up Check th...

Page 12: ...I 24068 Seriate BG via Pastrengo 3 b Phone 39 035 654311 www adbstagelight com IST01W 001 EN Rev 0 12 2019...

Reviews: