Osram 4008321189721 Manual Download Page 4

APPLICATIONS DALI MCU 

 

4. Installation 

 

The installation used in our example (figure 2) should be 

done as follows 

The mains supply to the luminaires and to one of the two 

DALI MCUs control devices may run through the same or 

through different phases (by means of a single conductor or 

by a 5-pole NYM cable). 

In our circuit, one of the two DALI MCUs control devices 

must be supplied with 230V mains power. The second 

control device will operate without a separate mains supply 

in the same control circuit. With this setup, you can control 

up to 25 ECG independent of their power consumption. Each  

DALI ECG comes with the interface that has a power 

consumption of approx. 2mA. The internal power supply of a 

DALI MCU connected to the mains will provide approx. 

52mA – enough to supply up to 25 ECG and another DALI 

MCU not connected to the mains.The following wiring 

diagram (figure 3), for example, shows that the control 

device labelled “Door A” has a mains connection. Likewise, 

the control device “Door B” could get the mains connection 

instead. This wiring diagram is based on the use of a 5-pole 

NYM cable and supply for the entire lighting system through 

one Phase (L and N).

4

 

Summary of Contents for 4008321189721

Page 1: ...changed at either of the control devices With the DALI MCU digital potentiometer it is easy to meet such requirements The parallel connection between the two devices control points which would be requ...

Page 2: ...the command triggered by the device last operated will determine the current switching state and or the brightness value in the room At the same time the command is transmitted to the other devices w...

Page 3: ...single pressure of the rotary knob and by turning the rotary knob to the left or right you can set the required brightness value Moreover you can also ask the DALI MCU to store a particular brightnes...

Page 4: ...me control circuit With this setup you can control up to 25 ECG independent of their power consumption Each DALI ECG comes with the interface that has a power consumption of approx 2mA The internal po...

Page 5: ...also connect the second control device to the 230V mains you can operate up to 50 luminaires and two additional DALI MCUs without mains connection in one and the same control circuit i e 4 control poi...

Page 6: ...exceed 300m It is important to observe correct polarity of the feed cables when connecting the control line with two or more DALI MCU control devices Because each of the devices has its own power sup...

Page 7: ...n also reset the system to its default setting in which the brightness value used before switching off the light will be restored when the light is switched back on the next time To do so switch off t...

Page 8: ...nnection between the two control circuits is broken Then lighting can be controlled and dimmed in both sections independently When the dividing wall is open the position switch is in closed position a...

Page 9: ...clude dimmable individual luminaires groups of luminaires custom settings in RGB colour mix systems with designer lamps or decorative lamps and the control of fluorescent lamps with different colour t...

Page 10: ...connection L N Operating voaltage 230 V AC 50 60 Hz Power consumption 3 W max DALI connection da da max 300 m cable legth 25 DALI ECG max Perm Cable cross section 1 4 mm 2 Ambient temperature 0 50 C T...