4
2. In Com Settings, select the serial interface, click the Open button to open
the serial port.
3. Choose the monitor you want to control.
4. The following settings can be changed:
(
1
)
Brighness control
(
2
)
Contrast control
(
3
)
Time code switch
(
4
)
Level meter function switch
(
5
)
UMD switch function. Enables the user to add text overlay to each display
up to 32 half-width characters. Click the Data Send button to apply the
setting.
3.Specifications
4. Included Accessories
1
.
15V DC power supply
2
.
RJ12 to DB9 Adapter for RS422
Note: Due to constant efforts of product improvements,
specifications may change without notice.
Panel
2 inch
Physical Resolution
640×240
Aspect Ratio
4 : 3
Brightness
250 cd/
㎡
Contrast
300: 1
Viewing Angle
80°/ 70°(H/V)
Input Signal
8×3G-SDI, RS422
Output Signal
8×3G-SDI
Input Voltage
DC12-24V
Operating Temperature
-20
℃
~ 55
℃
Storage Temperature
-30
℃
~ 70
℃
Power Consumption
≤23W
Dimension (LWD)
482.5×105×44mm
Weight
1555g