MX 12 pump kit - optional

For central heating systems

OSO  MX  12  pump  kit  contains  a  cir-

culation pump, shunt valve, air bubble 

vent valve and a 12 l. expansion vessel, 

factory assembled in an insulated and 

easy-to-fit cabinet. The kit can be fitted 

on either side of the EP2 water heater 

central, and is easily mounted on the 

wall next to the EP2.

The MX12 provides an easier and tidier 

way to assemble your heating system, 

and is in addition sound and heat insu-

lated. 

The subtle gray coloured cabinet hides 

the pump assembly and is both visually 

pleasing and energy effective, reducing 

heat loss from the components within.

The  MX  12  pump  kit  is  available  in 

selected countries, contact your OSO 

representative for further instructions. 

The OSO MX12 provides a tidy look to 

your installation, while at the same time 

reducing noise and saving energy from 

heat loss. 

Warranty

OSO hot water cylinder

 

The stainless steel inner vessel is guaranteed against material defect or manufacturing faults for 10 years from the date of purchase. 

Factory fitted electrical elements, thermostats and valves are guaranteed for a period of 2 years. The warranty does not cover ab-

normal limescale on the heating element and/or valves, or the body exposed to outside damages.

Conditions for warranty:

 

The water quality shall be in accordance with European Council Directive 98/83 EC, or revised version.

Chloride content:   

 

Max. 250 mg/l

Sulphate content:  

 

Max. 250 mg/l

Combination Chloride/sulphate: 

Max. 300 mg/l (in total)

1. The OSO cylinder must be installed in compliance with the OSO Installation & Maintenance Instructions, as well as all current 

    legislation and regulations governing the installation. 

2. The OSO cylinder is filled with water before turning the electricity supply on.

3. If the newly fitted water heater is not in regular use, it must be flushed through with fresh water for at least 15 minutes (open 

    hot water tap) once per week, during a period of at least 4 weeks. 

4. Defects caused by frost, excess pressure, salt dehardner process, transient voltage, lightning strikes or incorrect installation, 

    repair or use, are not covered by this warranty. 

5. Evidence of the purchase date and the date of supply must be submitted with your claim.

6. Original OSO spare parts must be used. 

Summary of Contents for Optima EP2

Page 1: ...______________________________ tel ______________________ date ______________ this manual is delivered to the user date ______________ aukt r rinstallat r ____________________________________________...

Page 2: ...ove safety valve 2 5 bar to ret pipe as shown IMPORTANT Check all pipe fittings for leaks Re check after one week of operation 1 2 3 4 5 Troubleshooting 1 No heat Check if pump is running Remove any a...

Page 3: ...Factory fitted Overflow pipes must be free flowing to gulley If HP is fitted move safety valve 2 5 bar to ret pipe as shown IMPORTANT Check all pipe fittings for leaks Re check after one week of opera...

Page 4: ...hermostat setting disconnect power supply Hw Reheater upper approx 75 C for bacteria safety Cw Mixing valve UX adjust to approx 55 C see below Central heating Main central lower to approx 70 C If heat...

Page 5: ...ews repeat after approx 3 months in service Optional effect power and temperatures Installation manual Supplied with product User manual sticker is applied to the unit Recyclable The water heater is 1...

Page 6: ...ecieve a lower temperature return which gives a high COP Electric peak power backup element is fitted near the top of the lower vessel as a safety for the central heating system It will back up the he...

Page 7: ...lectric Low temperature zone For pre heating of cold domestic water Energy in 1 Solar heat through lower coil Energy out 1 Domestic hot water Energy out 1 Central heating living area 2 Pre heating of...

Page 8: ...rs from the date of purchase Factory fitted electrical elements thermostats and valves are guaranteed for a period of 2 years The warranty does not cover ab normal limescale on the heating element and...

Page 9: ...s kning 1 Inte varmt Kontrollera att pumpen g r Lufta aktuell r rslinga eller radiator p nytt Kontrollera strypning av returventilen 2 F r lite varmvatten ppna ratten max p toppventilen Kontrollera st...

Page 10: ...KV VV r ren 22 sticks in i ventilen vrids 50 Nm KV ver 6 bar montera reduktionsventil Spilledning skall monteras S kerhetsventiler De fabriksmonterade verloppssr ren skall dras mot golvbrunn Monteras...

Page 11: ...VV Efterv rmer EL2 ca 75 s krar mot legionella mot VP VV Blandventil UX vrid ratten till ca 55 se nedan Golv rme Huvudcentral EL 1 ca 70 Om VP anv nds separat termostat VIKTIGT Shuntventil inst till...

Page 12: ...gar dras till kraftigt Kontrollera efter ca 3 m naders drift Valfri effekt koppling sp nning och temperaturer Montageanvisning Medf ljer inkluderat dokumentation Bruksanvisning i plast r p satt bereda...

Page 13: ...returtemperatur som vill ge en h g effektfaktor COP Elektrisk spetslast 3 6 kW 1 fas eller 9 kW 3 fas 230 400 V r placerad vid toppen av nedre magasinet f r att v rma direkt p centralv rmeanl ggningen...

Page 14: ...rme 2 V rmepump 3 Elektrisk L gtemperaturzon F rv rmning av kallt bruksvatten Energi in 1 Solv rme via nedre slingan r r vvx Energi ut 1 Varmt bruksvatten Energi ut 1 V rmeanl ggning rumsuppv rmning 2...

Page 15: ...ererats till OSO inom 2 veckor Vid leverans Kontrollera att produkten r oskadad Om skada eller annat fel uppst tt kontakta spedit ren eller terf rs ljaren innan produkten anv nds Garantivillkor 1 I fa...

Page 16: ...hink future http www osohotwater com OSO HOTWATER EXPORT AS Ma i n o f f i c e In d u s t r i v e i e n N 3300 Ho k k s u n d No r way Te l 47 32 25 00 00 Fa x 47 32 25 00 90 E m a i l o s o o s o n o...

Reviews: