6.1 Faults and fixes

If problems arise when the product is in use, 
check for possible faults and fixes in the table.
If you are unsure what is wrong, contact the 

6. TROUBLESHOOTING

TROUBLESHOOTING

Problem

Possible cause of fault

Possible solution

There is leakage/drip-

ping from the safety 

valve/there is often 

water on the floor by the 

cylinder in the morning

Pressure reduction valve, water meter 

or blocked non-return valve on the 

water intake.

Water pressure into the system is too 

high.

Fit AX expansion vessel which absorbs 

 

expansion during heating, and fit pressure 

reduction valve for stable water pressure  

inside the system. The pressure 

 

reduction valve is adjusted in according to the  

pressure in the expansion vessel. Contact 

auth. installer.

The safety valve is worn or there are  

particles stuck between the mem-

brane and the valve seat because the 

water is dirty

Try to flush with water through the safety 

valve. Open valve for approx. 1 minute. See 

section 5.2. If the valve still leaks, it must be 

replaced. Contact auth. installer.

Leak from heating element.

Verify as follows: a) cut the electric sup-

ply, b) unscrew the cover, c) visually check 

whether there is a leak from the heating 

element. If so, replace the gasket/heating 

element. Contact auth. installer.

No hot water

Power supply interrupted.

Verify that the fuse is on / the plug is 

plugged in to the wall contact / the earth 

breaker has not tripped.

Thermostat has cut out.

Press the ‘RESET’ button on the safety  

thermostat; see ‘User guide’.

Heating element is defective.

Replace heating element. Contact auth. 

installer.

Leak in hot water pipe

Verify as follows: a) close the water sup-

ply, b) wait 2-3 hours, c) feel the tank to 

see whether it is hot. If so, there is a leak 

in the hot water pipe or elsewhere. Con-

tact auth. installer.

Not enough hot water

High consumption in the system.

Switch to a larger OSO water heater.  

Contact auth. installer.

Not high enough  

temperature

The thermostat is set for low 

 

temperatures.

Check the thermostat settings. Turn up 

to 75°C; see ‘User guide’.

Change from cold to hot water in 

taps.

Contact auth. installer.

Fuse/earth breaker trips 

repeatedly

Possible fault in the heater’s electri-

cal system.

Verify as follows: a) cut the electric supply, 

b) unscrew the cover, c) visually check the  

junction box for any problems. If so, con-

tact auth. installer to check. Fit the cover.

Long time before the 

water reaches the tap

Long stretch of pipe from water 

heater to tap.

Fit circulation wire or heating cable to 

HW pipe. Or fit an auxiliary heater by 

the tap. Contact auth. installer.

Knocking in the pipes 

when the hot tap is 

closed

Large pressure increase when the 

tap is closed quickly.

Completely normal. Fit AX expansion  

vessel if troublesome. Contact auth. 

installer. 

installer (see product type plate) or OSO Hot-
water AS - see section 7.1.

Summary of Contents for 800 1854

Page 1: ...ay Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Maxi Geocoil MGC 600 1000 l NO SE EN SIKKERHETSINFORMASJON FDV INFORMASJON MONTASJEANVISNING S KERHETSINFORMATION FDV INF...

Page 2: ...i leveransen 6 3 3 Produktdimensjoner 6 3 4 Krav til installasjonssted 7 3 5 R r installasjon 8 3 6 El installasjon 10 4 Igangsettelse f rste gang 12 4 1 Fylling av vann 12 4 2 P settelse av str m 12...

Page 3: ...ngelige for fremtidig referanse Produsenten forutsetter overholdelse av sikkerhets drifts og vedlikeholdsinstruk ser som medf lger sluttbruker samt samsvar med montasjeanvisning gjel dende standarder...

Page 4: ...llinger skal kun utf res av personer over 18 r med tilstrekkelig kompetanse FORSIKTIG Produktet skal ikke utsettes for frost overtrykk overspenning eller klorbehandling Se garanti bestemmelser Vedlike...

Page 5: ...beidsmilj ISO 45001 2 2 Bruksomr de Maxi Geocoil er beregnet brukt som akkumulator for tappevann med el spisslast MGC er forberedt for ekstern energikilde 2 3 CE merking CE merket viser at produktet e...

Page 6: ...SINSTRUKS 3 1 Produkter omfattet av denne instruksen 800 1873 Maxi Geocoil MGC 600 3x230V 800 1854 Maxi Geocoil MGC 1000 3x230V 3 2 Medf lgende i leveransen Ref no Antall Beskrivelse 1 1 Akkumulatorta...

Page 7: ...t v tromsnormen siste TEK Alternativt skal aut vannstoppventil med sensor og overl p fra sikkerhetsventil til sluk monteres Produktansvar gjelder kun hvis dette blir fulgt Produktet skal plasseres i e...

Page 8: ...reduksjonsventil 3 5 2 Montering av r r A R r i egnet dimensjon legges frem til viste anslutninger og tilkobles med egnet tetn ingsmiddel Anslutninger som ikke benyttes m plugges forsvarlig B Produkte...

Page 9: ...vil forebygge mot evt materielle skader 3 5 4 Montasjeinstruks 3 5 5 Montasjeanbefaling FORSIKTIG Produktet skal plasseres i rom med sluk utf rt iht v tromsnormen siste TEK Alternativt skal aut vanns...

Page 10: ...yttes ved installasjon El montasje skal utf res av aut elektriker Gjel dende standarder og forskrifter skal f lges 3 6 2 Elektriske tilkoblinger i el boks RESE T R E S E T M 2 1 2 3 4 THERM O DISC 1 2...

Page 11: ...og at de er fri for skader 3 6 4 Montasjeinstruks 3 6 5 Montasjeanbefaling ADVARSEL Produktet skal v re fylt med vann f r str m tilkobles Fast el montasje skal benyttes ved installasjon iht forskrift...

Page 12: ...rostfritt m fall til sluk D Sjekk at produktet st r stabilt i lodd og i vater 4 5 Overlevering til sluttbruker 4 IGANGSETTELSE F RSTE GANG INSTALLAT R SKAL Instruere sluttbruker om sikkerhetsinstruks...

Page 13: ...v alle kompo nenter montert p eller i tanken Vedlikehold skal utf res av personer over 18 r med tilstrek kelig kompetanse rlig kontroll inkluderer Kontroll av tetthet ved anslutninger p alle komponent...

Page 14: ...Termostat har sl tt ut Trykk inn RESET knapp p sikkerhetster mostat se Brukerveiledning Varmeelement er defekt Skift varmeelement Kontakt aut instal lat r Lekkasje p varmtvannsr r Verifiser ved a ste...

Page 15: ...rutsetninger er fulgt Produktet har blitt installert i henhold til medf lgende montasjeanvisningogallerelevantereguleringer forskrifter normer og krav gjeldende p installasjonstidspunktet Produktet ik...

Page 16: ...ksund Norway Tel 47 32 25 00 00 oso oso no www osohotwater com Alle deler av denne montasjeanvisningen er beskyttet av ndsverksloven og skal ikke reproduseres eller distribueres uten skriftlig avtale...

Page 17: ...tured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E post oso oso no www osohotwater com Maxi Geocoil MGC 600 1000 l SE S KERHETSINFORMATION FDV INFORM...

Page 18: ...6 3 2 Vad som f ljer med i leveransen 6 3 3 Produktdimensioner 6 3 4 Krav p installationsplats 7 3 5 R rinstallation 8 3 6 Elinstallation 10 4 Uppstart f rsta g ngen 12 4 1 P fyllning av vatten 12 4 2...

Page 19: ...framtida anv ndning Tillverkaren f ruts tter att de medf l jande s kerhets drifts och underh llsin struktionerna slutanv ndaren f ljs samt att monteringsanvisningarna f ljs g llan de standarder och f...

Page 20: ...te befinna sig i n rheten av produkten obevakade Underh ll inst llningar f r endast utf ras av personer ver 18 r med tillr cklig kompetens HANTERAS VARSAMT Produkten f r inte uts ttas f r frost vertry...

Page 21: ...ohotwater com f r mer information OSO s produkter r designade och tillverkade en ligt Trycktanksstandard PED 2014 68 EU S kerhetsstandard EN 60335 2 21 Svetsstandard EN ISO 3834 2 OSO Hotwater AS har...

Page 22: ...45 Maxi Geocoil MGC 600 3x230V 693 81 52 Maxi Geocoil MGC 1000 3x230V 3 2 Vad som f ljer med i leveransen Ref nr Antal Beskrivning 1 1 Ackumulatortank med elektrisk spetslast coil 2 1 Installationsin...

Page 23: ...SAMT Produkten ska placeras i lokaler med avrinning golvbrunn Ansvar f r f ljdskador g ller endast om detta f ljs Produkten ska placeras i en torr och permanent frostfri milj Produkten ska placeras p...

Page 24: ...nsventil 3 5 2 R rmontering A R r i l mplig dimension l ggs framf r visade anslutningar och ansluts med l mp ligt t tningsmedel Anslutningar som inte anv nds m ste pluggas p ett l mpligt s tt B Produk...

Page 25: ...riserad vattenstoppsventil med sensor Detta kommer att f rebygga eventuella materiella skador 3 5 4 Monteringsinstruktion 3 5 5 Monteringsrekommendation HANTERAS VARSAMT Produkten ska placeras i loka...

Page 26: ...as 400V Internledningar V rmebest ndig Fast el montage ska anv ndas vid installation Elinstallation ska utf ras av auktoriserad elektriker G llande f reskrifter och standarder m ste f ljas 3 6 2 Elekt...

Page 27: ...llation enligt best mmelserna Elinstallation ska utf ras av auktoriserad elektriker Komponenter f r bortkoppling m ste ing i produktens el montage enligt g llande standarder och f reskrifter Str mkabe...

Page 28: ...samt har avrinning D Kontrollera att produkten st r stabilt b de v gr tt och lodr tt 4 5 Leverans till slutanv ndare 4 IG NGS TTNING F RSTA G NGEN INSTALLAT R SKA Informera slutanv ndaren om s kerhets...

Page 29: ...er 18 r med tillr cklig kompetens Kontroll inkluderar Kontroll av t thet vid anslutningar p alla komponenter och r rkopplingar terdras eller t tas p f rsvarligt s tt vid behov terdragning av alla elko...

Page 30: ...etstermosta ten se Bruksanvisning V rmeelementet r defekt Byt ut v rmeelementet Kontakta auktoriserad in stallat r L ckage p varmvattensr r Verifiera genom att a st nga av vattentillf rseln b v nta 2...

Page 31: ...s Produkten har installerats enligt de medf ljande installationsanvisningarna och alla relevanta f reskrifter regler normer och krav som g ller vid installationstillf llet Produkten har inte modifiera...

Page 32: ...way Tel 47 32 25 00 00 oso oso no www osohotwater com Alla delar av denna monteringsanvisning r upphovsr ttsskyddade och f r inte reproduceras eller distribueras utan skriftligt avtal med tillverkaren...

Page 33: ...ctured by OSO Hotwater AS Industriveien 1 3300 Hokksund Norway Tel 47 32 25 00 00 Fax 47 32 25 00 90 E mail oso oso no www osohotwater com Maxi Geocoil MGC 600 1000 l EN SAFETY INFORMATION O M INFORMA...

Page 34: ...6 3 3 Product dimensions 6 3 4 Requirements for installation location 7 3 5 Pipe installation 8 3 6 Electrical installation 10 4 Initial commissioning 12 4 1 Filling with water 12 4 2 Turning on the p...

Page 35: ...y are accessible for fu ture reference The manufacturer assumes compli ance by the end user with the safety operating and maintenance instructions supplied and by the installer with the fit ting manua...

Page 36: ...be carried out by persons over 18 years of age with sufficient understanding CAUTION The product must not be exposed to frost over pressure over voltage or chlorine treatment See warranty provisions...

Page 37: ...Conformity at www osohotwater com for more information OSO products are designed and manufactured in accordance with Pressure vessel standard PED 2014 68 EU Safety standard EN 60335 2 21 Welding stand...

Page 38: ...ucts covered by these instructions 800 1873 Maxi Geocoil MGC 600 3x230V 800 1854 Maxi Geocoil MGC 1000 3x230V 3 2 Included in delivery Ref no Num ber of Description 1 1 Buffer tank with electrical pea...

Page 39: ...The manufacturer assumes no respoansibility whatsoever if this provision is not followed The product should be placed in a dry and permanently frost free position The product should be placed on a fl...

Page 40: ...ted by installing a pressure reduction valve 3 5 2 Fitting pipes A Run a pipe of suitable size to the connec tions shown and affix with suitable sealant Unused connections must be plugged se curely B...

Page 41: ...ith sensor This will prevent possible material damage 3 5 4 Fitting instructions 3 5 5 Fitting recommendation CAUTION The product shall be placed in a room with a floor drain The manufacturer assumes...

Page 42: ...ical fittings must be used for instal lation Any electric fittings must be installed by an authorised electrician The relevant standards and regulations must be followed 3 6 2 Electrical connections i...

Page 43: ...commendation WARNING The product should be filled with water before the power is switched on Fixed electrical fittings must be used for installation according to the regulations Any electric fittings...

Page 44: ...d frost free with a fall to the drain D Check that the product is standing firmly vertically and horizontally 4 5 Handover to end user 4 INITIAL COMMISSIONING THE INSTALLER MUST Brief the end user on...

Page 45: ...or to the product must be inspected annually Inspection must be per formed by person older than 18 years of age with appropriate qualifications Annual inspection in cludes Checking all connections fo...

Page 46: ...Verify that the fuse is on the plug is plugged in to the wall contact the earth breaker has not tripped Thermostat has cut out Press the RESET button on the safety thermostat see User guide Heating e...

Page 47: ...oduct has not been modified in any way tampered withorsubjectedtomisuseandnofactoryfittedpartshave been removed for unauthorized repair or replacement TheProducthasonlybeenconnectedtoadomesticmains wa...

Page 48: ...l 47 32 25 00 00 oso oso no www osohotwater com This installation manual and all its content is protected by copyright and may be reproduced or distributed only with written consent from the manufactu...

Reviews: