5 Assembly and installation
16
CVP High-Pressure Centrifugal Pump
5 Assembly and installation
NOTICE
Material damage due to contamination!
► Only remove covers, transport caps and
sealing caps immediately before connecting
the pump to the pipelines.
CAUTION
Ensure compliance with all safety specifi-
cations during installation and operation.
1. Please consult the manufacturer when
installing at altitudes over 1000 m
above mean sea level.
5.1.1 Preparing the installation loca-
tion
► Ensure that the installation location meets
the following conditions:
–
pump is freely accessible from all
sides
–
sufficient space for installing/removing
piping, as well as for maintenance and
repair work, in particular for in-
stalling/removing the pump and motor
–
no effects from external vibrations on
the pump (bearing damage)
–
protection against frost
5.1.2 Preparing the base surface and
foundations
► Ensure that the base surface and founda-
tions meet the following conditions:
–
level
–
clean (no oils, dust or other contami-
nations)
–
foundations can support the weight of
the pump unit and all operating forces
–
stability of the pump unit ensured
5.2 Installation
5.2.1 Installing the pump
Prior to installation, remove the packaging (if
present) and check the pump for any transport
damage. Ensure that the installation area is
dry and free of frost.
CAUTION
Do not operate the pump in areas where
there is a risk of explosion. Ensure that the
pump is installed and connected in line
with the local regulations.