Oslo OSP1-08 Use And Care Manual Download Page 3

Safety Instructions 

1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If 

you have any questions regarding to the following instructions, please contact a qualified electrician. 

2. The unit must be installed in accordance with national wiring regulations. Check available power supply 

and resolve any wiring problems before installation and operation of this unit. 

3. For your safety and protection, this unit will be grounded through the power cord plug when plugging into 

a matching wall outlet. If you are not sure whether the wall outlet at your home are properly grounded, 

please consult an electrician. If supply cord is damaged, it must be replaced by the manufacturer, its service 

agent or similarly qualified person in order to avoid any hazards. 

4. This appliance is not intended for people  (including children)  with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. Young children should be 

supervised to ensure that they do not play with the appliance. 

 

 

WARNING

 

To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow up these basic 

precautions: 

 

Indoor use only, it is prohibited to use this unit outdoors or in humid environment such as bathroom etc. 

 

Do not remove ground prong. 

 

Do not use an adapter. 

 

Do not use an extension code. 

 

Never share the power outlet with other appliances. 

 

Never connect or disconnect the power plug with wet hands to avoid electric shocks. 

 

Never turn off the unit by unplugging. 

 

Unplug air conditioner before servicing. 

 

Never dismantle, repair or modify the unit without authorization to avoid body injury or property damage, 

be sure it repaired by manufacturer or professionals. 

 

After the air conditioning    installation, please ensure that the wires plug in good condition and securely 

inserted into the power socket, and always maintain the power cord placement rules orderly, avoid 

someone stumbled or pull the plug out. 

 

Never put any objects into the unit. 

 

Never cover or obstruct air inlet or outlet to prevent overheating.   

 

Never hit or shake the unit to prevent damage. 

 

Never spray water or place the unit near water to prevent electric shocks. 

 

Never place the unit near gas appliances, fire or flammable liquids. 

 

Move and install the unit by two or more people. 

 

The unit should be far away from the gas, flammable gas, stoves, or other heat source 

 

This appliance can be used by children aged from 8 years and above and persons with reduced 

physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 

 

2

Summary of Contents for OSP1-08

Page 1: ...l Thank you very much for selecting this new model of Portable Air Conditioner please read this Use and Care Manual carefully before installing and using this appliance Please keep this Use and Care M...

Page 2: ...ification 3 Features and Identification of Parts 4 Operation and Settings 5 Protection 7 Handling and Transportation 8 Installation and Adjustment 9 Drainage Instruction 11 Maintenance and Service 13...

Page 3: ...conditioner follow up these basic precautions Indoor use only it is prohibited to use this unit outdoors or in humid environment such as bathroom etc Do not remove ground prong Do not use an adapter D...

Page 4: ...efore disassembling or installing the filter Remark Do not use this unit in cooling mode if the ambient temperature is higher than 35 Function and Technical Specification This unit offers cooling heat...

Page 5: ...ll 4 Universal wheel 5 Back shell 6 Handle 7 Filter 8 Universal socket 9 Wire winding pillar 10 Drain hole and cover 11 Up filter assemble 12 Down filter assembly 13 Chassis 14 Remote control 15 Exhau...

Page 6: ...2 Press the UP DOWN arrow buttons to select the number of hours you want the unit to continue to operate before turning on Note wait approximately 5 seconds for the Turn On time to be saved To clean t...

Page 7: ...power supply F CONTROL PANEL DISPLAY Displays the set temperature in degrees Fahrenheit or degrees Celsius or the hours remaining in a Time Delay The corresponding indicator light will illuminate 2 Re...

Page 8: ...lace Notes Use alkaline batteries only Do not use rechargeable batteries When replace batteries always replace both batteries with new batteries do not mix old and new batteries If the air conditioner...

Page 9: ...E1 If sensors test ok unit restore original state of work or enter into standby state when energized Handling and Transportation 1 Handle and move the unit 1 Hold handles on side panels to move the u...

Page 10: ...xhaust hose assembly and its adapter 1 Take out the exhaust hose assembly and its adapter from plastic bag 2 Extend the exhaust hose at one end screw the round end of adapter into exhaust hose at anti...

Page 11: ...er downwards B Lock self tapping screw 4mm into adapter hole 3 Remarks Slide the adapter downwards and assure the adapter installed in good position Lock the 4 screw tightly to avoid fall off Exhaust...

Page 12: ...pper properly 3 Tilt the unit slightly backwards when draining 4 Block the drain hole as soon as possible before the tray is full if it can t hold all water in the unit to prevent the water leakage an...

Page 13: ...Pull the drain hose to bathroom or outdoor Notes 1 Drain hose must be installed before unit starts working 2 Put the drain hose in an inaccessible place not higher than water outlet and keep drain ho...

Page 14: ...filter 1 Grip the filter handle and take it out gently in correct direction shown by the arrow 2 Hold hand positions with your hands take filters out in correct direction shown by the arrow Note 1 Us...

Page 15: ...ar insert the plug into the universal fixing hole at the back panel of the unit install the water plug and drain cap 4 Remove the heat exhaust hose assembly clean and keep it properly Note 1 Hold the...

Page 16: ...e the filter Air inlet or air outlet clogged Remove the obstruction High noise level The unit is being placed at uneven surface Put the unit at a flat and firm place may reduce noise The compressor do...

Page 17: ...otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship Damage caused by consumer misuse tampering or failure to follow the care and special hand...

Reviews: