osily OSEF User Manual Download Page 21

21

EN

S

S

ON

1 2 3 4

ON

1 2 3 4

ON

1 2 3 4

L

N

L

N

L

N

L(2)

N(3)

LT(1)

L(2)

N(3)

LT(1)

L(2)

N(3)

... 150 Z1T

... 150 Z1PCT

Operation mode 1

Operation mode 2

Operation mode 3

Fan does not run

S switch to ON

or pull cord switch

Activation of turn-off

delay timer (0-2 minutes)

S switch is OFF

during countdown of turn-on

delay timer

Yes

No

Fan runs at speed 1

S switch to ON

or pull cord switch

Fan does not run

S switch to ON

or pull cord switch

Activation of turn-off

delay timer (0-2 minutes)

S switch is OFF

during countdown of turn-on

delay timer

Fan runs at speed 2

S switch to ON

or pull cord switch

Да

Нет

Fan runs at speed 1

S switch to ON

or pull cord switch

Fan runs at speed 2

S switch is OFF

during countdown of turn-on

delay timer

No

Yes

Activation of turn-off

delay timer (0-2 minutes)

S switch to ON

or pull cord switch

15.

Summary of Contents for OSEF

Page 1: ...User s manual OSEF AXIAL FAN EN...

Page 2: ...is a main operating document intended for technical maintenance and operating staff The manual contains information about purpose technical details operating principle design and installation of the...

Page 3: ...ians with a work permit for electrical units up to 1000V are allowed for installation The present user s manual should be carefully read before beginning works Check the unit for any visible damage of...

Page 4: ...unit to adverse atmospheric agents rain sun etc Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use the unit in a hazardous or explos...

Page 5: ...vision or instruction concerning use of the unit by a person responsible for their safety Children should be supervised to ensure that they do not play with the unit Precautions must be taken to avoid...

Page 6: ...nsure that the unit is switched off from the supply mains before removing the guard THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC...

Page 7: ...for connection to single phase AC power mains Power supply parameters are stated on the unit packaging and or the label on the unit casing Ingress protection rating against access to hazardous parts...

Page 8: ...tional options Z1 base model Z1PC pull cord switch Z1T turn off delay timer Z1PCT pull cord switch and turn off delay timer Z1H humidity sensor and turn off delay timer Z1PIR motion sensor Colour C Ch...

Page 9: ...f Fig 3 Step 2 Run the power cable to the vent hole Fig 4 Step 3 Remove the front panel from the fan Then remove the circuit board cover Fig 5 Step 4 Mark and drill holes for mounting the fan fasten t...

Page 10: ...from 0 up to 2 minutes off To adjust the fan turn off delay time turn the control knob Toff clockwise to increase and counter clockwise to decrease the turn off delay time respectively adjustable fro...

Page 11: ...speed 1 by default The fan switches to the speed 2 when the switch is turned on or a sensor is activated Operation mode 4 two speed The fan is turned off by default The fan starts operating at low spe...

Page 12: ...ndicator blinks green once in a second the turn on delay time is activated 60 seconds 3 The light indicator glows red the humidity sensor is activated and the fan runs at high speed 4 The light indica...

Page 13: ...e into contact with electric components TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond to any controls...

Page 14: ...hinery for handling and storage operations to prevent possible damage to the unit Follow the handling requirements applicable for the particular type of cargo Theunitcanbecarriedintheoriginalpackaging...

Page 15: ...ific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the...

Page 16: ...Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to ci...

Page 17: ...17 EN 1 2 Dimensions mm D B H L L1 OSEF 150 148 214 190 111 32 B D L L1 H...

Page 18: ...18 EN 3 4 5 6 7 8 9 10 11...

Page 19: ...run S switch to ON or pull cord switch Fan runs at speed 1 S switch to OFF or pull cord switch S S LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 L N L N L N 150 Z1 speed 2 150 Z1PC speed 2 Fan does not run...

Page 20: ...L N LT 1 L 2 N 3 LT 1 L 2 N 3 LT 1 L 2 N 3 150 Z1 speed 1 and 2 150 Z1PCT speed 1 and 2 speed 1 and 2 Fan does not run S switch to ON or pull cord switch Speed switch Fan runs at speed 1 Fan runs at...

Page 21: ...ay timer Yes No Fan runs at speed 1 S switch to ON or pull cord switch Fan does not run S switch to ON or pull cord switch Activation of turn off delay timer 0 2 minutes S switch is OFF during countdo...

Page 22: ...turn on delay timer 0 2 minutes S switch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord...

Page 23: ...FF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan does not run Fan runs at speed 2 F...

Page 24: ...ch is OFF during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at...

Page 25: ...during countdown of turn on delay timer Humidity exceeds set point No No No Yes Yes Yes S switch to OFF or pull cord switch S switch to ON or pull cord switch Fan runs at speed 2 Fan runs at speed 1...

Page 26: ...ch to ON or pull cord switch Yes Humidity exceeds set point No Fan runs at speed 1 Fan runs at speed 1 Fan runs at speed 1 Fan does not run Fan runs at speed 2 Fan runs at speed 1 Fan runs at speed 1...

Page 27: ...t speed 2 Fan runs at speed 1 No motion detected Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Activation of turn off delay timer 2 30 minutes Fan doe...

Page 28: ...28 EN 22 23 24 25...

Page 29: ...29 EN...

Page 30: ...30 EN...

Page 31: ...31 EN Quality Inspector s Stamp Manufacture Date Sold by name and stamp of the seller Purchase Date...

Page 32: ...YESSS_Electrical_235 2EN 01 OSEF 150 C Z1PC Z1H Z1T Z1PCT Z1PIR...

Reviews: