SECTION 3 – MACHINE CONTROLS, INDICATORS AND OPERATION
3-36
– JLG Lift–
3.16 BATTERY CHARGING
NOTE:
Be sure that the machine is parked in a well-ventilated area before charging
begins.
ONLY PLUG THE CHARGER INTO A PROPERLY INSTALLED AND GROUNDED
OUTLET. DO NOT USE GROUND ADAPTORS OR MODIFY PLUG. DO NOT TOUCH
NON-INSULATED PORTION OF OUTPUT CONNECTOR OR NON-INSULATED BAT
-
TERY TERMINAL.
DO NOT OPERATE CHARGER IF THE AC SUPPLY CORD IS DAMAGED OR IF THE
CHARGER HAS RECEIVED A SHARP BLOW, BEEN DROPPED OR OTHERWISE
DAMAGED IN ANY WAY.
ALWAYS DISCONNECT THE AC SUPPLY BEFORE MAKING OR BREAKING THE
(POS/NEG) CONNECTIONS TO THE BATTERY.
DO NOT OPEN OR DISASSEMBLE CHARGER.
The battery charger
AC input plug (1)
is located in the bat
-
tery compartment, under the access door.
1.
Connect the
AC input plug (1)
to a grounded outlet.
2.
When powered up, the charger will go through a short
self-test and automatically start the charge.
3.
The batteries are fully charged when the battery
charging indicator is solid green (See Charger Inter
-
face).
NOTE:
If the charger is left plugged in, the charger will automatically restart a complete
charge cycle if the batteries voltage drops below 24.96 V or 30 days has elapsed.
(1)
To
order
go
to
Discount-Equipment.com