SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION
2-6
– JLG Lift –
3121214
SEE DETAIL A
DETAIL A
Figure 2-1. Boom Cutout Switches
UPPER BOOM ANGLE TO BE 1° BELOW HORIZONTAL TO 3°
ABOVE HORIZONTAL TO ACTIVATE SWITCH. UPPER BOOM
ANGLE TO BE 1° TO 4° BELOW HORIZONTAL TO RESET SWITCH.
LOWER BOOM ANGLE TO BE 1° TO 5° ABOVE
HORIZONTAL TO ACTIVATE SWITCH. LOWER
BOOM ANGLE TO BE 0° TO 5° BELOW
HORIZONTAL TO RESET SWITCH.
Property of American Airlines