SECTION 2 - PROCEDURES
2-30
– JLG Lift –
3121801
2.19 ELECTRONIC CONTROL SYSTEM
Hand Held Analyzer
To Connect the Hand Held Analyzer
1. Connect the four pin end of the cable supplied with
the analyzer, to the top connection of the motor con-
troller and connect the remaining end of the cable to
the analyzer.
NOTE:
The cable has a four pin connector at each end of
the cable; the cable cannot be connected back-
wards.
2. Power up the Control System by turning the lower
key to the platform position and pulling both emer-
gency stop buttons on.
men u:
PRESS ENTER
HELP:
Analyzer Display
Escape Key
To return home or access
previous menu
Enter Key
Stores and selects Top Level, Sub
Level, and item menus
Left & Right Arrow Keys
Used to move between Top Level,
Sub Level, and item menus
Up & Down Arrow Keys
Value Selector