oserio FEG-115 Series Instruction Manual Download Page 16

Refer to page19 for setting user profile.

6

7

Note: 

1. Press              to turn on.

2. Welcoming and running calibration.

3.Calibration is completed. 

   Press 

         

to start selecting user No.

4. Select User No.

5. Show User No.  

6. Press             to modify user profile.

7. Modify age, gender, height item by item.

The unit will shut down automatically if you do not touch any buttons within 60 seconds.
Press 

        

for 2 seconds to turn off.

3

2

1

5

4

Press

(DO NOT

 step on the platform)

Press           to start selecting user No.

Press           to select user No.

No.2 user profile has been set

Press          to confirm entries

2.6 Modifying User Profile

Operating Instructions

Next Page

User profile

27

26

Summary of Contents for FEG-115 Series

Page 1: ...on manual at hand all the time for future reference Authorized EU Representative Manufactured by Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C Manufacturer s De...

Page 2: ...Health conscious Professional Innovative...

Page 3: ...e 2 3 Measuring Body Composition 2 4 Viewing Measurement Values 2 5 Viewing Historical Values 2 6 Modifying User Pro le 2 7 Error Message List More Information 3 1 Care and Maintenance 3 2 Product Spe...

Page 4: ...r Mode is for visitors using and the measurement reading will be erased from the memory 5 Data reference from Body fatness and risk for elevated blood pressure total cholesterol and serum lipoprotein...

Page 5: ...ght and to estimate the value of the Bio Impedance body composition Product use Body Fat BMI BMR and Body Weight Measuring Principle Biological impedance Analysis BIA works together with such as gende...

Page 6: ...olarities of the battery compartment as indicated 9 Remove the batteries if the unit not be used for three months or longer 10 If the display not shows check the batteries 11 Do not mix old and new ba...

Page 7: ...manufacturer s declaration electromagnetic emissions The FLG 351 FEG 113 FEG 123 FEG 115 is intended for use in the electromagnetic environment speci ed below The customer or the user of the FLG 351...

Page 8: ...e Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV di erential mode Not applicable Mains power qualit...

Page 9: ...dio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to xed RF transmitters an electromagnetic site survey should be considered...

Page 10: ...G 113 FEG 123 FEG 115 as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W For transmitters rated at a maximum output...

Page 11: ...ion of the graphic symbols SN 135 00001 Designation of the serial number of every device applied at the device Number as an example Please note the accompanying documents or Observe operating instruct...

Page 12: ...isitor s pro le will not be kept in memory The unit will shut down automatically if you do not touch any buttons within 60 seconds Press for 2 seconds to turn o Press to start selecting user No Press...

Page 13: ...ot be kept in memory The unit will shut down automatically if you do not touch any buttons within 60 seconds Press for 2 seconds to turn o 3 2 1 5 4 Press DO NOT step on the platform Press to start se...

Page 14: ...s DO NOT Step o and remain still until body fat is shown STAY Step o and view the values Operating Instructions 3 seconds View user s reading after measuring body composition 1 Body Fat 2 Body Mass In...

Page 15: ...is selected press to view historical values While viewing user s reading after measuring body composition press to view historical values No historical values are memorized for visitor Press 1st memo...

Page 16: ...modify user pro le 7 Modify age gender height item by item The unit will shut down automatically if you do not touch any buttons within 60 seconds Press for 2 seconds to turn o 3 2 1 5 4 Press DO NOT...

Page 17: ...ow power but still workable while ickers 8 11 9 10 Remain still and do not move until the measurement is completed STEP ON Press to con rm entries Note Operating Instructions 2 6 Modifying User Pro le...

Page 18: ...panels 10 Prevent water in ltration a ecting the measurement accuracy Model Body Fat Monitor FEG 115 Note 1 Body fat measurement is for users age 10 80 2 Speci cations may be changed without prior no...

Reviews: