B. EMC Guidance and Manufacturer's Declaration 

 

Guidance and manufacturer’s declaration-electromagnetic emissions 

The BHG-208 Cardio Scale is intended for use in the electromagnetic environment specified 

below. The customer or the user of the product should assure that it is used in such an 

environment. 

Emission test   

Compliance   

Electromagnetic 

environment-guidance   

RF emissions CISPR 11   

Group 1   

The product uses RF energy only for 

its internal function. Therefore, its 

RF emissions are very low and are 

not likely to cause any interference 

in nearby electronic equipment.   

RF emissions CISPR 11   

Class B   

The product is suitable for use in all 

establishments, including domestic 

establishments and those directly 

connected to the public low-voltage 

power supply network that supplies 

buildings used for domestic 

purposes.  

Harmonic emissions IEC 

61000-3-2   

Class A   

Voltage fluctuations /flicker 

emissions IEC 61000-3-3  

Compliance  

 

Guidance and manufacturer’s declaration-electromagnetic immunity 

The BHG-208 Cardio Scale is intended for use in the electromagnetic environment specified 

below. The customer or the user of the product should assure that it is used in such an 

environment.  

Immunity test 

IEC 60601 

test level 

Compliance 

level 

Electromagnetic 

environment-guidance 

Electrostatic 

discharge(ESD)  

IEC 61000-4-2   

±

  8 kV contact 

±

  2 kV, ± 4 kV, 

± 8 kV, ± 15 kV 

air 

±

  8 kV contact 

±

  2 kV, ± 4 kV, 

± 8 kV, ± 15 kV 

air 

Floors should be wood, concrete 

or ceramic tile. If floors are 

covered with synthetic material, 

the relative humidity should be 

at least 30%  

Electrical fast 

transient/burst 

IEC 61000-4-4   

± 2kV for 

power supply 

lines   

+ 1kV for 

input/output 

lines   

+ 2kV for power 

supply lines 

+ 1kV for 

input/output 

lines 

Mains power quality should be 

that of a typical commercial or 

hospital environment.  

Surge IEC 

61000-4-5   

± 1kV line(s) to 

line(s)   

± 2kV line(s) to 

earth  

+ 1kV line(s) to 

line(s) 

+ 2kV line(s) to 

earth 

Mains power quality should be 

that of a typical commercial or 

hospital environment.  

Summary of Contents for BHG-208

Page 1: ...1 User Manual BHG 208 Cardio Scale Please keep the instruction manual at hand all the time for future reference...

Page 2: ...is user manual is protected by international copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liabl...

Page 3: ...escription 6 A Overview 6 B Inserting Batteries 7 III How to Use 8 A Self calibration 8 B Conducting measurement 8 IV Caring for your product 10 A Use Storage 10 B Service and maintenance 10 V Trouble...

Page 4: ...le flat solid non slippery surface Place the product in an area free from direct sunlight heating equipment high humidity or extreme temperature change Never submerge in water Usage on soft surfaces e...

Page 5: ...ice with operational Bluetooth and Wi Fi is required to download the o Care app and retrieve measurement results from the product QR Code QR Code Google Play Android Devices App Store Apple Devices Af...

Page 6: ...6 II Product Description A Overview 1 LED screen 2 Measurement platform 3 Feet 4 Battery cover...

Page 7: ...over Insert 3 AAA batteries Replace battery cover NOTE Ensure batteries are inserted in correct orientation If batteries are inserted incorrectly product will not function If product will not be used...

Page 8: ...no carpet To ensure accuracy we recommend performing self calibration if product is moved Open o care app on smartphone and log in Results will be automatically transferred after measurement so it is...

Page 9: ...results 1 If o care app is not open on smartphone results will not be transferred Product will automatically shut down 30 seconds after completion of heart rate measurement 2 Ensure that Bluetooth is...

Page 10: ...o not use detergents or cleaners to clean the product This may damage the coating protecting the electrodes used for body composition measurement Wipe the platform and display using clean soft cloth A...

Page 11: ...s product s maximum capacity Stay still and avoid movement during measurement Data transfer error Data sent from smartphone to product resulted in error Try measurement again Data transfer error Data...

Page 12: ...Product 290 W x 300 D x 25 H mm Screen 76 W x 42 5 D mm Operation Environment Temperature 5 35 Relative Humidity 30 85 Storage Environment Temperature 20 60 Relative Humidity 10 95 Capacity Graduatio...

Page 13: ...ations flicker emissions IEC 61000 3 3 Compliance Guidance and manufacturer s declaration electromagnetic immunity The BHG 208 Cardio Scale is intended for use in the electromagnetic environment speci...

Page 14: ...the electromagnetic environment specified below The customer or the user of the product should assure that is used in such an environment Immunity test IEC 60601 test level Compliance level Electroma...

Page 15: ...rtable and mobile RF communications equipment and the BHG 208 Cardio Scale The product is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The custom...

Page 16: ...sion Yangzhou Co Ltd No 28 Xinyang Rd Development Zone Yangzhou City Jiangsu Province 225009 P R China on behalf of Charder Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O...

Reviews: