1700 891 69-1    EN    01/12/2021

IMPORTANT

READ CAREFULLY BEFORE USE
SAVE FOR FUTURE REFERENCE

Osby Parca EL 36 & 50 Eco 

 

– Modern electric boilers with new touchscreen

Installation and Operating Instructions

Osby Parca 

Tel. no.: +46 (0)479 177 00 | [email protected] | www.osbyparca.se | Box 93, 283 22 Osby, SWEDEN

The Professional’s Choice Since 1935

MADE IN

SWEDEN

Summary of Contents for EL 36 Eco

Page 1: ...FUTURE REFERENCE Osby Parca EL 36 50 Eco Modern electric boilers with new touchscreen Installation and Operating Instructions Osby Parca Tel no 46 0 479 177 00 sales osbyparca se www osbyparca se Box...

Page 2: ...2 EL 36 50 Eco...

Page 3: ...__________________________ 18 9 4 1 Alarm description _________________________ 19 9 4 2 Alarm messages __________________________ 19 9 4 3 Alarm history _____________________________ 20 9 5 Advanced_...

Page 4: ...r installer This will enable the electric boiler to function in good condition for a long time It will then produce the heat you need at the lowest total cost for many years to come Note Fill in the i...

Page 5: ...product Turn off the safety switch before performing any work on the product Please note that the boiler requires both 400 V supply along with 230 V supply for the control system The product may not...

Page 6: ...of glycol but as a rule of thumb the following changes will occur A 25 glycol mixture reduces output by approx 10 A 35 glycol mixture reduces output by approx 15 A 50 glycol mixture reduces output by...

Page 7: ...ending on the type of control signal eg 0 10 V or 230 V ext blocking electricity If control signal is used you define in the control system how to control the boiler external control exter nal control...

Page 8: ...eeping track of when servicing needs to be carried out This can be set with the touchscreen in the Service menu Error messages are also displayed here along with suggestions for how to rectify the err...

Page 9: ...9 EL 36 50 Eco Instructions for re tightening Osby Parca EL 36 och EL 50 Eco 2 12 Nm 3 2 8 Nm 6 2 8 Nm 4 AF26 2 5 Nm AF12 1 5 Nm 1 0 8 Nm 5 Immersion heaters 1 8 Nm beneath the lid...

Page 10: ...36 5 2 7 400 V 52 63 40 7700110 11 36 5 2 7 230 V 91 100 40 7700120 01 50 8 3 6 400 V 72 80 40 7700120 11 50 8 3 6 230 V 125 160 40 Design pressure 4 0 bar Testing pressure 5 7 bar Design temperature...

Page 11: ...0 V 1 x 48 mm F Connection 230 V Separate power supply 230 V 1 is required for operating voltage For the touch screen a cable of 3 m length is delivered already connected to the cabinet The feet are a...

Page 12: ...0 1 0 24 0 3 50 24 9 1 1 0 36 0 4 50 24 9 0 0 1 36 0 5 66 33 2 1 0 1 48 0 6 83 41 5 0 1 1 60 0 7 100 49 8 1 1 1 72 7700120 11 Kw 8 3 16 6 24 9 R 1 R 2 R 3 CURRENT Step kW K1 K3 K2 K4 1 17 8 3 1 0 0 20...

Page 13: ...No Image Designation 7641437 01 1 Stand for EL 36 Eco and EL 50 Eco H 500 mm 3366 9005 2 GSM Alarm with battery back up 584196401 3 Outdoor temperature sensor incl 15 m cable 1118404 01 4 3 st current...

Page 14: ...ies come with factory set values as standard These are monitored by the control system which constantly ensures optimal functionality and economical operation These values can be easily changed if req...

Page 15: ...15 EL 36 50 Eco 8 Menu overview Home screen Alarm menu Advanced settings menu Operating time energy calculator and highest boiler temperature menu...

Page 16: ...16 EL 36 50 Eco Advanced settings menu Display menu Settings menu Define system menu Service menu Quick start menu System information menu...

Page 17: ...s can be viewed and the function can be overridden System information Here you ll find information about the boilers serial number article number etc Return Press the Return button to return to the pr...

Page 18: ...his menu screen 9 2 1 Main menu when external control If external control is active the set point from the external signal is shown here If control via power the set point is shown in C If control via...

Page 19: ...u will be displayed along with a message describing the alarm e g E10 Com error BMS If several alarms are active they will be displayed sequentially A persisting fault must first be rectified before i...

Page 20: ...tings for time language and the actual diplay Settings are used by both the installer and user to set values and functions Define system is used to define how the boiler is to be controlled to specify...

Page 21: ...the flags and then OK Under Display setup you can set these parameters Sleep delay time in seconds before the screen turns off 0 Backlight brightness of the screen 10 100 Click sound should touch scre...

Page 22: ...0 100 Max flow temp desired boiler temperature same as on the start page 0 100 C Min flow temp lowest permissible temperature for the boiler 0 100 C Step rate time between entry of power exit is alwa...

Page 23: ...get a quick start it is recommended that you set DHCP to Yes and let the network assign all required addresses Then the time is also adjusted and the communication starts To access the mirroring of th...

Page 24: ...Always active Outdoor temp compensation Active Disabled Prim flow temp reduction Active Disabled Current measurement Active Disabled Prim current transformer ratio 10 2000 in steps of 10A Sec current...

Page 25: ...tions Alarm dumps export the alarm log to USB for trouble shooting Function test see status of all inputs and outputs Inputs are grey and outputs white the white ones may be managed When leaving the m...

Page 26: ...n off Inputs 230 V Safety circuit 230 V Ext shut off Flow temp reduced Tariff Outdoor sensor Room sensor external Start Stop Boiler temp sensor Internal temp board sensor External set point Phase curr...

Page 27: ...f produced kWh and shows a reset prompt Pressing OK resets the calculator to zero PIN code is required to access the menu 9 6 6 Reset history The menu shows a reset history prompt Pressing OK resets t...

Page 28: ...wnshifts and enters OFF mode When the circuit is closed again the boiler first enters STANDBY mode and then once the step duration permits ON mode 9 7 External power 9 8 Outdoor Compensation Once an e...

Page 29: ...t to 55 C The lowest temperature is 27 C summer time compensation or systems unable to tolerate very high temperatures 9 8 3 Heating curve ascension inclination The curve can be set between 30 and 60...

Page 30: ...ection Stage duration Stage duration can be increased in the Settings menu NOTE Initial stage duration cannot be adjusted or changed It is fixed at 16 seconds 9 10 Delta T deadband The function of del...

Page 31: ...nges the regulator follows the signal and shifts up every 16 seconds 9 13 Output control 9 14 Current limitation If necessary the output of the boiler can be limited when for example the current drawn...

Page 32: ...5 33540 10 41800 5 52400 0 66200 5 84750 10 108000 15 139000 20 181000 25 238000 Boiler temp sensor NTC 22 k Temperature C NTC 22 k Resistance 70 32 65 37 60 43 55 51 50 60 45 72 40 85 35 102 30 123 2...

Page 33: ...Direktiven 2014 30 EU EMC direktivet och 2014 35 EU L gsp nningsdirektivet Directive 2014 30 EU EMC directive and 2014 35 EU Low Voltage Directive Ecodesign 811 2013 EU labelling and 813 814 2013 EU...

Page 34: ...heater compl 25 kW 230 V 485 7112185 02 Packing cartridge EL 36 EL 50 Also refer to the spare parts list at the circuit diagram for the actual boiler Control system Boiler kW Art no Designation 36 50...

Page 35: ...35 EL 36 50 Eco...

Page 36: ...ch AB Osby Parca div Tel 46 0 479 177 00 sales osbyparca se www osbyparca se Box 93 SE 283 22 Osby SWEDEN 13 Appendices Circuit diagram Warranty document Subject to errors or updates made after this e...