Matrix Installation and Operation Manual
30 ______________________________________________________________________________
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES* FROM PIPE CONNECTOR
TO THE COMBUSTIBLE MATERIALS
CANADA
USA
D
18½" (470 mm)
18½" (470 mm)
E
26½" (673 mm)
26½" (673 mm)
F
19½" (495 mm)
19½" (495 mm)
DISTANCES* FROM PIPE CONNECTOR
TO THE COMBUSTIBLE MATERIALS
CANADA
USA
D
9½" (241 mm)
9½" (241 mm)
E
24½" (622 mm)
24½" (622 mm)
F
15½" (394 mm)
15½" (394 mm)
*The pipe distances listed in this table refer to the distances obtained when the stove is installed
in accordance with the appliance clearances above mentioned. However, you can install the
stove at reduced clearances; follow the instructions in Section 7.4:
Reducing Wall and Ceiling
Clearances Safely
. Where they are followed, the new distance of the pipe to combustible
materials must be respected in the appropriate certification of the pipe.
Clearances for mobile homes
MOBILE HOME APPLIANCE CLEARANCES (INSTALLATION
WITH DOUBLE WALL PIPE CONNECTOR)
CANADA
USA
A
10" (254 mm)
10" (254 mm)
B
17" (432 mm)
17" (432 mm)
C
8" (203 mm)
8" (203 mm)
K
48" (1219 mm)
48" (1219 mm)
L
84" (213 cm)
84" (213 cm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES* FROM PIPE CONNECTOR TO THE
COMBUSTIBLE MATERIALS
CANADA
USA
D
13½" (343 mm)
13½" (343 mm)
E
27½" (699 mm)
27½" (699 mm)
F
17½" (445 mm)
17½" (445 mm)
*The pipe distances listed in this table refer to the distances obtained when the stove is installed
in accordance with the appliance clearances above mentioned. However, you can install the
stove at reduced clearances; follow the instructions in Section 7.4:
Reducing Wall and Ceiling
Clearances Safely
. Where they are followed, the new distance of the pipe to combustible
materials must be respected in the appropriate certification of the pipe.